Purpose: SAR245408 is a pan-class I phosphoinositide 3-kinase (PI3K) inhibitor. This phase I study determined the maximum tolerated dose (MTD) of two dosing schedules [first 21 days of a 28-day period (21/7) and continuous once-daily dosing (CDD)], pharmacokinetic and pharmacodynamic profiles, and preliminary efficacy.Experimental Design: Patients with refractory advanced solid malignancies were treated with SAR245408 using a 3 þ 3 design. Pharmacokinetic parameters were determined after single and repeated doses. Pharmacodynamic effects were evaluated in plasma, hair sheath cells, and skin and tumor biopsies.Results: Sixty-nine patients were enrolled. The MTD of both schedules was 600 mg; dose-limiting toxicities were maculopapular rash and hypersensitivity reaction. The most frequent drug-related adverse events included dermatologic toxicities, diarrhea, nausea, and decreased appetite. Plasma pharmacokinetics showed a median time to maximum concentration of 8 to 22 hours, mean terminal elimination half-life of 70 to 88 hours, and 5-to 13-fold accumulation after daily dosing (first cycle). Steady-state concentration was reached between days 15 and 21, and exposure was dose-proportional with doses up to 400 mg. SAR245408 inhibited the PI3K pathway ($40%-80% reduction in phosphorylation of AKT, PRAS40, 4EBP1, and S6 in tumor and surrogate tissues) and, unexpectedly, also inhibited the MEK/ERK pathway. A partial response was seen in one patient with advanced non-small cell lung cancer. Eight patients were progression-free at 6 months. Pharmacodynamic and clinical activity were observed irrespective of tumor PI3K pathway molecular alterations.Conclusions: SAR245408 was tolerable at doses associated with PI3K pathway inhibition. The recommended phase II dose of the capsule formulation is 600 mg administered orally with CDD. Clin Cancer Res; 20(1); 233-45. Ó2013 AACR.
BACKGROUND AND PURPOSE:Anterior communicating artery (AcomA) aneurysm is the most frequent form of aneurysm. Stent placement is particularly difficult and of limited use for AcomA aneurysms. We report our experience with stent-assisted embolization for wide-neck AcomA aneurysms in 21 patients. Particular attention is given to the morphologic characteristics and strategy of stent deployment.
This trial showed an obviously higher rate of large and giant aneurysm obliteration with the Tubridge FD over Enterprise stent-assisted coiling. However, this higher obliteration rate came at the cost of a nonsignificantly higher rate of complications. Investigational site comparisons suggested that a learning curve for flow-diverter implantation should be recognized and factored into trial designs.
BackgroundWingspan stenting for the treatment of complex intracranial atherosclerotic stenosis (ICAS), i.e., that involving tortuous vascular pathways, long (>15 mm) lesions or arterial bifurcations, has a relatively high risk of complications. This retrospective study assessed the safety and efficacy of undersized balloon angioplasty followed by deployment of the more flexible Enterprise stent for the treatment of complex symptomatic ICAS.MethodsForty-four patients on combined antiplatelet therapy and intensive risk factor management and a symptomatic 70–99 % stenosis of a major intracranial artery in complex settings that was treated with balloon angioplasty and Enterprise stent deployment between July 2009 and August 2013 were enrolled. Primary outcome was occurrence of ischemic or hemorrhagic stroke or death within 30 days after intervention. Secondary outcomes included procedural success (defined as achievement of <50 % immediate residual stenosis), and follow-up clinical and angiographic outcomes.ResultsWith a procedural success rate of 100 %, stenosis was reduced from 79.3 ± 8.1–14.9 ± 12.3 %. Three (6.8 %) ischemic and 1 (2.2 %) hemorrhagic strokes occurred during the periprocedural period, with no further transient ischemic attacks or strokes in the 42 patients available at median 25.6 (range, 12–57) months follow-up. Of the 38 (86.4 %) patients who underwent angiographic follow-up, 3 (6.81 %) developed >50 % in-stent restenosis after mean 22 months follow-up.ConclusionIn this retrospective, single-center experience, undersized balloon angioplasty followed by Enterprise stent deployment appears technically feasible with a relatively low rate of complications for the treatment of complex symptomatic ICAS. Prospective, multicenter, randomized controlled trials against optimal medical management are warranted.
IntroductionFew studies focused on predictors of unfavorable outcomes (modified Rankin Scale, 2–6) after reconstructive treatment of the ruptured intracranial spontaneous vertebral artery dissection aneurysms (ris-VADAs), which was evaluated based on 57 reconstructed lesions in this study.MethodsResults of 57 consecutive patients (M:F = 29∶28; median age, 48 years; range, 27 to 69 years) harboring 57 ris-VADAs, which were treated with coils combined with single stent(n = 32), double overlapping stents (n = 16), and triple overlapping stents (n = 9) between October 2000 to March 2011, were retrospectively reviewed and analyzed.ResultsThe available (n = 54) mean durations of angiographic and clinical follow-ups were 27 months (range, 12 to 78) and 62 months (range, 12 to 132), respectively. The involvement of PICA (p = 0.004), size of lesions (p = 0.000), quantity of stent (p = 0.001), and coil type (p = 0.002) affected the immediate obliteration grade, which was only risk factor for angiographic recurrences (p = 0.031). Although the post-treatment outcomes did not differ between single stent and multiple stents (p = 0.434), 5 angiographic recurrences, 1 rebleeding and 1 suspected rebleeding, all occurred in partial obliteration after single-stent-assisted coiling. Progressive thrombosis and in-stent obliteration were not detected on follow-up angiograms. Older age (odds ratio [OR] = 1.090; 95% confidence interval [CI], 1.004–1.184; p = 0.040) and unfavorable Hunt-Hess scale (OR = 4.289; 95%CI, 1.232–14.933; p = 0.022) were independent predictors of unfavorable outcomes in the reconstructed ris-VADAs.ConclusionsImmediate obliteration grade was only risk factor for angiographic recurrence after reconstructive treatment. Unfavorable Hunt-Hess grade and older age were independent predictors of unfavorable outcomes in ris-VADAs.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.