SYNOPSIS
This study examines the relationship between CEO turnover in client companies and the fees charged by their audit firms. We propose that forced CEO turnover (such as dismissals) pose higher business and audit risks for the audit firm than voluntary turnover (such as retirements); further, greater risk leads to higher audit prices. We develop a regression model of audit fees that includes, as predictor variables, type of CEO turnover and control variables identified in prior studies (e.g., ROA, total assets, and corporate governance). Results reveal that companies with forced CEO turnover have significantly higher audit fees than companies with either voluntary turnover or no turnover. Further, we find no difference in audit fees between firms with voluntary turnover and firms without turnover.
Data Availability: The data used in this study are publicly available.
This work presents a model behind the operation of a flow-through sampling chip and its application for immunoseparation, as well as its integration with a wash/elution bed for protein purification, concentration, and detection. This device used hydrodynamic pressure to drive the sample flow, and a gating voltage was applied to the electrophoretic channel on the microchip to control the sample loading for the separation and to inhibit sample leakage. The deduced model indicates that the critical gating voltage (VC) that is defined as the minimum gating voltage applied to the microchip for sampling is a function of the pump flow rate, the configuration of the microchannel on the chip, and the electroosmosis of the buffer solution. It was found that the theoretical V(C) values calculated from the measured electroosmotic mobilities and flow split ratios were comparable to those experimentally obtained from two microchips with different sampling channel sizes. This had an error percentage ranging from 1 to 20%. Because the hydrodynamic flow is insensitive to electrophoretic mobility, this electrophoresis-based microchip device was free of injection bias due to different ionic strength and electrophoretic mobility in the sample. Additionally, the usefulness of this device was demonstrated for the study of affinity interactions. Mixtures of Cy5-labeled bovine serum albumin (Cy5-BSA) and anti-BSA in various proportions were introduced into the microchip via a syringe pump, and the immunocomplex was electrophoretically separated from the free Cy5-BSA on the microchip. Based on the relative intensity of the free and complex BSA, the binding constant of BSA and anti-BSA was estimated as 3.3 x 10(7) M(-1). Furthermore, a C18 microcartridge (20 microL) was connected to the hydrodynamic inlet of the microchip. Using this device, the wash/elution step can be integrated on-line with the electrophoretic separation and detection on the microchip. Results show that the calibration curve of Cy5-BSA obtained from this integrated device has an R2 value greater than 0.99 and a minimum of quantitation at approximately 10 ng. This direct sampling method is another means of subfractionation, resulting in a relatively greater concentration factor than the average concentration of the whole fraction. Moreover, the electrical field-free bed ensures that the protein interaction will not be affected by the electric field during the wash/elution step.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.