A sensitive determination of a synthetic fluoroquinolone antibacterial agent, moxifloxacin (MOX), by an enhanced chemiluminescence (CL) method using a microfluidic chip is described. The microfluidic chip was fabricated by a soft-lithographic procedure using polydimethyl siloxane (PDMS). The fabricated PDMS microfluidic chip had three-inlet microchannels for introducing the sample, chemiluminescent reagent and oxidant, and a 500 µm wide, 250 µm deep and 82 mm long microchannel. An enhanced CL system, luminol-ferricyanide, was adopted to analyze the MOX concentration in a sample solution. CL light was emitted continuously after mixing luminol and ferricyanide in the presence of MOX on the PDMS microfluidic chip. The amount of MOX in the luminol-ferricyanide system influenced the intensity of the CL light. The linear range of MOX concentration was 0.14-55.0 ng/mL with a correlation coefficient of 0.9992. The limit of detection (LOD) and limit of quantification (LOQ) were 0.06 and 0.2 ng/mL respectively. The presented method afforded good reproducibility, with a relative standard deviation (RSD) of 1.05% for 10 ng/mL of MOX, and has been successfully applied for the determination of MOX in pharmaceutical and biological samples.
A simple and selective method to determine norfloxacin using an optical flow-through sensor has been developed. The present sensor was prepared by packing anionic ion exchange resin in a glass tube, followed by introducing KMnO(4) solution to the glass tube for immobilization on resin. The optical sensor is based on the emission intensity from the Tb(III) solution sensitized by norfloxacin. The excitation of norfloxacin occurred by the chemiluminescence from the reaction of KMnO(4) and Na(2)SO(4) solutions. The effects of pH, concentration of Tb(III) ion, KMnO(4) and Na(2)SO(4) solutions and flow rate of the norfloxacin solution on the chemiluminescence intensity were studied to find the optimum experimental conditions. The emission intensity increased linearly with increasing norfloxacin concentration from 1.0 x 10(-3) to 1.0 x 10(-8) M and the detection limit (3sigma) was 8.7 x 10(-9). The applicability of the present method was demonstrated by determination of norfloxacin in various pharmaceutical preparations and serum sample.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.