SUMMARYCentralized semi‐active control is a technique for controlling the whole structure using one main computer. Centralized control systems introduce better control for relatively short to medium high structures where the response of any story cannot be separated from the adjacent ones. In this paper, two centralized control approaches are proposed for controlling the seismic response of post‐tensioned (PT) steel frames. The first approach, the stiffness control approach, aims to alter the stiffness of the PT frame so that it avoids large dynamic amplifications due to earthquake excitations. The second approach, deformation regulation control approach, aims at redistributing the demand/strength ratio in order to provide a more uniform distribution of deformations over the height of the structure. The two control approaches were assessed through simulations of the earthquake response of semi‐actively and passively controlled six‐story post‐tensioned steel frames. The results showed that the stiffness control approach is efficient in reducing the frame deformations and internal forces. The deformation regulation control approach was found to be efficient in reducing the frame displacements and generating a more uniform distribution of the inter‐story drifts. These results indicate that centralized semi‐active control can be used to improve the seismic performance of post‐tensioned steel frames. Copyright © 2014 John Wiley & Sons, Ltd.
The concept of passive control of the seismic response of structures was introduced to improve the performance of structures by increasing their energy dissipation and reduce or eliminate damage in the structural elements. The key task in the design of passive systems is to determine the forces in the control devices (yield/slip or post-tensioning) at each floor, that will result in best performance (e.g. minimum inter-storey drift). This can be achieved by large parametric studies in which both the maximum control force (e.g. at ground level) and the distribution of forces along the height of the structure are varied. Alternatively, optimum forces in the devices can be achieved by semi-active control, where the structure self-adapts to the earthquake. Both solutions are expensive: the first requires hundreds of non-linear response simulations in the design stage; the second needs a system of sensors, controllers and electromechanical devices. Presented here is a new Self-Adaptive Optimisation Approach (SAOA) in which the self-optimisation of a semi-active system is used in the design stage and the resulting distribution of control forces is adopted as a passive system. The new approach was evaluated through comparing the simulated dynamic responses of two relatively simple benchmark structures (braced and post-tensioned) with three sets of control forces: (i) passive system with forces obtained in parametric study, (ii) semi-active system with self-adapting control forces, and (iii) passive system with SAOA-optimized forces. The results show good performance of the SAOA systems, indicating that SAOA offers a simple and effective solution that can replace the existing optimisation approaches for the design of passively controlled earthquake resistant structures. This study presents a novel idea of using the semi-active control as a tool for optimising a passive control system. The passive control systems can be further improved by a larger study in which the semi-active control algorithms are also optimised.
Nada Elkady and colleagues describe their research-based work to design a steel transfer truss resistant to progressive collapse. The project won the Institution's Research into Practice case study competition in 2022.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.