BackgroundAlthough initial studies of neuroendovascular intervention did not review benefit over intravenous thrombolytics (iv r-tPA), recent studies have suggested otherwise. Elderly patients (age ≥80 years) are typically excluded from clinical trials.PurposeTo examine the utility of mechanical thrombectomy based on patient outcomes.Material and MethodsAll stroke-alert activations at our health system from January 2011 to June 2014 were examined. All patients aged ≥80 years who had undergone mechanical thrombectomy were identified. Clinical characteristics included physiologic imaging findings, use of intravenous thrombolytics, baseline and postoperative National Institute of Health Stroke Scale (NIHSS), thrombolysis in cerebral infarction scores (TICI), and discharge destination.ResultsMean NIHSS on presentation was 18.2 (range, 6–31), and 13.3 (range, 3–30) post thrombectomy. Three (16.6%) patients received iv r-tPA, two (11.1%) had symptomatic intracranial hemorrhage. Eight (44.4%) died, eight (44.4%) were discharged to nursing homes, and two (11.7%) were discharged to inpatient rehab and subsequently home. Favorable outcome was achieved in five (27.7%) patients. Fourteen (77.7%) patients had physiologic imaging prior to intervention. Three (75%) of four patients who did not have physiologic imaging prior to thrombectomy died. Thirteen (66.6%) patients had TICI 3 recanalization.ConclusionOur study showed that although there remains a role of mechanical thrombectomy in the treatment of acute ischemic stroke in very elderly patients, it is associated with significant higher morbidity and mortality compared to younger patients, but should remain a very viable treatment option when quality of life is the most important consideration.
Using this selective approach at LSUHSC, in which the operative rate was 9%, acceptable outcomes were obtained both in patients not having surgery and also in those having surgical intervention.
SUMMARYDuring treatment of a right internal carotid artery terminus aneurysm, an acute iatrogenic flow limiting dissection was caused in the cervical internal carotid. The true lumen was catheterized using a Mirage 0.008 microwire over an Excelsior SL-10 microcatheter, which was exchanged for a Marksman microcatheter. A 6 mm×30 mm Solitaire FR revascularization device was then deployed across the dissection as a salvage technique.
BACKGROUND
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.