Introduction: Plaque accumulation and bond failure are drawbacks of orthodontic treatment, which requires composite for bonding of brackets. As the antimicrobial properties of TiO2 nanoparticles (NPs) have been proven, the aim of this study was to evaluate the antimicrobial and mechanical properties of composite resins modified by the addition of TiO2 NPs. Methods: Orthodontics composite containing 0%, 1%, 5% and 10% NPs were prepared. 180 composite disks were prepared for elution test, disk agar diffusion test and biofilm inhibition test to collect the counts of microorganisms on three days, measure the inhibition diameter and quantify the viable counts of colonies consequently. For shear bond strength (SBS) test, 48 intact bovine incisors were divided into four groups. Composites containing 0%, 1%, 5% and 10% NPs were used for bonding of bracket. The bracket/tooth SBS was measured by using an universal testing machine. Results: All concentration of TiO2 NPs had a significant effect on creation and extension of inhibition zone. For S. mutans and S. sanguinis, all concentration of TiO2 NPs caused reduction of the colony counts. Composite containing 10% TiO2 NPs had significant effect on reduction of colony counts for S. mutans and S. sanguinis in all three days. The highest mean shear bond strength belonged to the control group, while the lowest value was seen in 10% NPs composite. Conclusions: Incorporating TiO2 nanoparticles into composite resins confer antibacterial properties to adhesives, while the mean shear bond of composite containing 1% and 5% NPs still in an acceptable range.
Background
Long-term retention with fixed retainers with a high success rate seems to be a reasonable solution to minimize or prohibit relapse of orthodontic treatment.
Methods
Two hundred sixty patients between 13 and 30 years old were recruited for this study. The 0.0175 stainless steel twisted wire (G&H Orthodontics, USA) was compared with a single-strand ribbon titanium lingual retainer wire (Retainium, Reliance orthodontics, USA) was used. When treatment was completed, the retainers were bonded from canine to canine in the mandibular arch of the participants. In the follow-up visits, the patients were recalled every 3 months during the 24 months. Detachments, the time of debonding, and side effects were recorded. Statistical analysis was performed by a blinded statistician using a statistical package for Social Science (SPSS, Version20). After descriptive statistics, Kaplan-Meier analysis was performed to measure the survival rates of each retainer. P value < 0.05 was considered as significant.
Results
Finally, 138 patients who received twisted wire splint and 112 patients who received ribbon wire were included in the analysis. The average duration of success was about 23 months for twisted wire and ribbon wire, according to the Kaplan-Meier estimates. The analysis showed no significant overall difference between the treatments (p = 0.13). Failure rates in terms of detachments in all groups occurred at the enamel junction, and it was 25 in twisted retainer group (18.1%) and was 10 in ribbon retainer group (8.9%); the Kaplan-Meier analysis test detected a significant difference in the failure rates between the groups (p = 0/006).
Conclusions
Although the conventional twisted stainless steel wire and single-strand titanium flat metal ribbon wire as fixed orthodontic retainers have the same clinical effects, it was shown that the ribbon wire has less failure in terms of detachments.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.