Objectives:
To evaluate tuberosity union rate and clinical outcome after 3- and 4-part proximal humerus fractures in the elderly.
Design:
Retrospective, multicenter database cohort study.
Setting:
Level I and Level II trauma centers.
Patients:
Fifty-five patients older than 65 years had insertion of reverse shoulder arthroplasty (RTSA) for OTA/AO 11-B and 11-C proximal humerus fractures.
Intervention:
Treatment with RTSA using a dedicated low profile onlay fracture stem using variable tuberosity fixation.
Main Outcome Measures:
Constant score, the American Shoulder and Elbow Surgeons score, Shoulder Pain and Disability Index score, University of California at Los Angeles score, Simple Shoulder Test score, visual analog pain score, shoulder function score, active range of motion, external rotation (ER)-specific tasks and position, rate of greater tuberosity healing, effect of tuberosity healing on overall clinical metrics, incidence of humeral lucency, and scapular notching.
Results:
Eighty-three percent of the greater tuberosities that were repaired united. Greater tuberosity union resulted in greater active ER (P = 0.0415). There was a statistically significant difference in the ability to do ER-type activities between the 2 cohorts reflected in the ability to position one's hand behind their head with the elbow forward (P = 0.002) and comb their hair (P < 0.001).
Conclusion:
The use of a low profile onlay fracture stem in RTSA for acute 3- and 4-part proximal humerus fractures in the elderly can result in a high tuberosity union rate. Greater tuberosity healing significantly influences ER and ER-type activities that are not apparent by analysis of the overall metrics studied.
Level of Evidence:
Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.
This study provides recommendations on the position of the implant in reverse shoulder replacement in order to minimise scapular notching and osteophyte formation. Radiographs from 151 patients who underwent primary reverse shoulder replacement with a single prosthesis were analysed at a mean follow-up of 28.3 months (24 to 44) for notching, osteophytes, the position of the glenoid baseplate, the overhang of the glenosphere, and the prosthesis scapular neck angle (PSNA). A total of 20 patients (13.2%) had a notch (16 Grade 1 and four Grade 2) and 47 (31.1%) had an osteophyte. In patients without either notching or an osteophyte the baseplate was found to be positioned lower on the glenoid, with greater overhang of the glenosphere and a lower PSNA than those with notching and an osteophyte. Female patients had a higher rate of notching than males (13.3% vs 13.0%) but a lower rate of osteophyte formation (22.9% vs 50.0%), even though the baseplate was positioned significantly lower on the glenoid in females (p = 0.009) and each had a similar mean overhang of the glenosphere. Based on these findings we make recommendations on the placement of the implant in both male and female patients to avoid notching and osteophyte formation.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.