Wearable pressure sensing solutions have promising future for practical applications in health monitoring and human/machine interfaces. Here, a highly sensitive, low-cost, wearable pressure sensor based on conductive single-walled carbon nanotube (SWCNT)/alginate hydrogel spheres is reported. Conductive and piezoresistive spheres are embedded between conductive electrodes (indium tin oxide-coated polyethylene terephthalate films) and subjected to environmental pressure. The detection mechanism is based on the piezoresistivity of the SWCNT/alginate conductive spheres and on the sphere-electrode contact. Step-by-step, we optimized the design parameters to maximize the sensitivity of the sensor. The optimized hydrogel sensor exhibited a satisfactory sensitivity (0.176 ΔR/R0/kPa(-1)) and a low detectable limit (10 Pa). Moreover, a brief response time (a few milliseconds) and successful repeatability were also demonstrated. Finally, the efficiency of this strategy was verified through a series of practical tests such as monitoring human wrist pulse, detecting throat muscle motion or identifying the location and the distribution of an external pressure using an array sensor (4 × 4).
The design strategy and mechanical response mechanism of light-activated, rapid-response, flexible films are presented. Practical applications as a microrobot and a smart spring are demonstrated.
Fiber‐based, flexible pressure‐sensing systems have attracted attention recently due to their promising application as electronic skins. Here, a new kind of flexible pressure‐sensing device based on a polydimethylsiloxane membrane instrumented with double‐twisted smart threads (DTSTs) is reported. DTSTs are made of two conductive threads obtained by coating cotton threads with carbon nanotubes. One thread is coated with a homogeneous thickness of single‐walled carbon nanotubes (SWCNTs) to detect the intensity of an applied load and the other is coated with a graded thickness of SWCNTs to identify the position of the load along the thread. The mechanism and capacity of DTSTs to accurately sense an applied load are systematically analyzed. Results demonstrate that the fabricated 1D, 2D, and 3D sensing devices can be used to predict both the intensity and the position of an applied load. The sensors feature high sensitivity (between ≈0.1% and 1.56% kPa) and tunable resolution, good cycling resilience (>104 cycles), and a short response time (minimum 2.5 Hz). The presented strategy is a viable alternative for the design of simple, low‐cost pressure sensors.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.