Excessive lead has been found in drinking water in Hong Kong in tests carried out in 2015. Investigations have identified that the problem in public rental housing estates was caused by the problematic solders used in the plumbing, and recommendations on enhancing the quality control system and strengthening the relevant water quality standards have been proposed. The cause for the same problem happening in other premises where soldering has not been adopted for water pipe connections is left unidentified. Considering the unidentified cause and the recommendations made, this study aims to identify the gaps in practice followed in Hong Kong for safeguarding the water quality of new installations. A holistic review of governing ordinances and regulations, products and materials used and the testing and commissioning requirements adopted in Hong Kong and elsewhere in the world were conducted. Based on international practices and parametric analysis, it was found that there are gaps in practices followed in Hong Kong, which are directly and indirectly leading to the lead-in-water crisis. Recommendations for improvement in the quality control system, and the water quality standards including the allowable lead content and leaching limit for products and materials and the testing and commissioning requirements on plumbing installations have been made. The review and the identified gaps would become useful reference for countries in strengthening their relevant water quality standards.
Abstract:A novel dedicated outdoor air system (DOAS) comprising a multi-stage direct expansion coil to produce extra-low temperature (XT) outdoor air to handle the entire space cooling demand has been confirmed more efficient than conventional systems. To further enhance the performance of XT-DOAS, the optimum number of cooling stages and treated outdoor air temperature need to be determined. This process requires the development of a coil performance model that takes into account the extra-high and extra-low entering air temperatures at the first and the last cooling stages. In this study, factory test data and field measurement data were used to develop such a performance model. Different statistical analyses were employed to validate the developed model. Based on the developed model, energy and exergy analyses were conducted to evaluate use of XT-DOAS for space cooling of a typical office building in Hong Kong. EnergyPlus was employed for the energy analysis. The laws of thermodynamics were used for the exergy analysis. Their combined results indicate that for better energy efficiency and performance for air-conditioning of office buildings in subtropical region, the optimum configuration for XT-DOAS is two cooling stages with a treated outdoor air temperature of 7 • C. The model developed and the energy and exergy analyses described will contribute significantly to future research in this area.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.