Purpose: To examine the contribution of anterior chamber depth (ACD), lens thickness (LT), and white-to-white (WTW) measurements to intraocular lens (IOL) power calculations using the Barrett Universal II (BUII) formula. Methods: Measurements taken with the IOLMaster 700 (Carl Zeiss, Meditec AG, Jena, Germany) swept-source biometry of 501 right eyes of 501 consecutive patients undergoing cataract extraction surgery between January 2019 and March 2020 were reviewed. IOL power was calculated using the BUII formula, first through the inclusion of all measured variables and then by using partial biometry data. For each calculation method, the IOL power targeting emmetropia was recorded and compared for the whole cohort and stratified by axial length (AL) of the measured eye. Results: The mean IOL power calculated for the entire cohort using all available parameters was 19.50 ± 5.11 diopters (D). When comparing it to the results obtained by partial biometry data, the mean absolute difference ranged from 0.05 to 0.14 D; p < 0.001. The optional variables (ACD, LT, WTW) had the least effect in long eyes (AL ≥ 26 mm; mean absolute difference ranging from 0.02 to 0.07 D; p < 0.001), while the greatest effect in short eyes (AL ≤ 22 mm; mean absolute difference from 0.10 to 0.21 D; p < 0.001). The percentage of eyes with a mean absolute IOL dioptric power difference more than 0.25 D was the highest (32.0%) among the short AL group when using AL and keratometry values only. Conclusions: Using partial biometry data, the BUII formula in small eyes (AL ≤ 22 mm) resulted in a clinically significant difference in the calculated IOL power compared to the full biometry data. In contrast, the contribution of the optional parameters to the calculated IOL power was of little clinical importance in eyes with AL longer than 22 mm.
Introduction: Randomized controlled trials that compared direct oral anticoagulants (DOACs) to vitamin K antagonists (VKA) for the treatment of venous thromboembolism (VTE), demonstrated both efficacy and safety of DOACs. The aim of the current study was to compare DOACs to VKA for the treatment of VTE in the elderly, in a real-life setting. Methods: A retrospective cohort study was performed in Rabin Medical Center encompassing a 7-year period. Hospitalized patients >65 years, with a diagnosis of VTE discharged with DOACs or VKA were included. The primary outcome was a composite of all-cause mortality, major bleeding, recurrent VTEs and hospitalizations throughout the follow-up period of one year. Results: A total of 603 patients were included in the final analysis. The mean age was 79.6 ± 8.5 years. The primary composite outcome occurred in 74.6% and 56.7% of the patients in the VKA group and DOACs group, respectively, hazard ratio 0.59, 95% confidence interval 0.46 to 0.76, in favor of the DOACs group. In a matched cohort analysis, the results were the same as the original analysis. Conclusion: In the elderly population, treatment of VTE with DOACs was associated with a lower rate of the composite outcome. DOACs are safe and effective for elderly patients with VTE.
Early dropout and treatment adherence are main challenges in the treatment of children with obesity. The aim of this study was to identify factors associated with attrition and adherence to weight loss intervention program. We retrospectively reviewed the medical records of all the children who entered the program for pediatric weight loss over 5 years and retrieved demographic and clinical characteristics. Attrition and adherence were documented. Ninety-two of the 248 enrolled children (52% women, mean age 11.1 ± 3.9 years, mean body mass index 31.1 ± 7 kg/m2) dropped out (37%). Dropping out correlated with male sex, low parental education, and self-referral to the clinic ( P < .05 for all). Adherence correlated with older age and the mother’s healthy lifestyle ( P < .05 for all). Sex, parental education, and referral source may predict treatment attrition. Early recognition of children at risk of attrition may help to facilitate better care of those children.
Purpose: To compare the accuracy of the Barrett Universal II (BUII) fivevariable formula to previous generation formulae in calculating intraocular lens (IOL) power following paediatric cataract extraction. Methods: Retrospective study of consecutive paediatric patients who underwent uneventful cataract extraction surgery along with in-the-bag IOL implantation between 2012 and 2018 in the Hospital for Sick Children,
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.