EST is a safe and effective nonsurgical mode of therapy in controlling esophageal variceal bleeding in children with EHPVO. Significant variceal bleeding did not occur during the relatively short follow-up in this series.
High-resolution 1H-NMR spectroscopy of serum and urine samples of an 11-year-old male living related orthotopic liver transplant recipient is reported. Serum glutamine increased to abnormal levels along with simultaneous abnormal excretion of urinary glutamine post-transplantation. High levels of glutamine in both blood and urine and concomitant reduced urea levels in urine were found to be evidence of impairment in urea cycle and compatible with persistently abnormal graft function. Thus glutamine levels in serum and urine, and urea in the urine as observed by 1H-NMR spectroscopy highlight their important roles in monitoring liver graft function; increased glutamine levels lead to brain damage, if untreated.
Background & Aims:Early detection of raised intracranial pressure (ICP) improves outcome in acute liver failure (ALF). We evaluated the feasibility of bedside, ultrasound-guided measurement of optic nerve sheath diameter (ONSD) in normal and ALF children and correlation of ONSD with grade of hepatic encephalopathy (HE), international normalized ratio (INR) and blood ammonia (BA).Methods: Forty-one ALF and 47 healthy children (5-18 years) were prospectively enrolled and 12 hourly clinical evaluation was done. Laboratory parameters including INR and BA were recorded. ONSD was measured at admission, change in HE grade and at recovery in ALF, and once in controls.
Results:One hundred and twenty-one ONSD measurements were taken without complications. ONSD was 4.2 (3.9-4.3), 4.4 (4.0-4.6), 5.2 (4.8-5.8) and 3.9 (3.3-4.1) mm in controls, ALF without HE, with HE and at recovery respectively. ONSD was significantly higher in ALF with HE than those without HE. ALF without HE and at recovery had ONSD similar to controls. ONSD was higher in ALF with the clinical signs of raised ICP than those without (5.4 [4.9-5.7] vs 4.6 [4.1-5.3] mm; P = .01). ONSD of 4.6 mm differentiated ALF with HE vs without HE and 5.1 mm between poor vs good non-transplant outcome with ≥80% sensitivity and specificity. ONSD positively correlated with INR (r = .53, P < .001) and BA (r = .42, P = .002).
Conclusions: ONSD can be safely and easily measured in ALF children and correlates with HE grade, INR and BA. Normal ONSD in children (>4 years) is <4.5 mm and value of >5.1 mm in ALF requires urgent attention. K E Y W O R D S acute liver failure, children, hepatic encephalopathy, optic nerve sheath diameter | 429 DAS et Al.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.