Tip clearance between blade end and shroud is inevitable in pump operation and of great importance on pump energy performance and pressure fluctuation. As the tip clearance size increases, the head and efficiency of the mixed flow pump drop accordingly. The simulation results show that the development of a leakage vortex is observed as the tip clearance increases, and the trajectory of this leakage vortex remains in the same direction along the blade suction side for different tip clearances. With the increase in tip clearance size, the intensity of the leakage vortex is enhanced, and the separation between the main leakage vortex and the secondary leakage vortex is also strengthened. The leakage separation angle near the blade tip remains at the same value of 10° for different tip clearance sizes. As for the spectrum analysis, the maximum amplitudes of pressure fluctuations dramatically increase in the impeller when the tip clearance increases from 0.0 mm to 1.0 mm, and the dominant frequencies go from 145 Hz to 184 Hz due to the considerable leakage flow.
Abstract:The energy performance and pressure fluctuations in a centrifugal pump with inlet guide vanes (IGVs) are investigated experimentally and numerically in a prewhirl angle range of −24 • to 24 • and in an axial distance range of 280 mm, 380 mm, and 460 mm. The reliability and accuracy of the numerical method are validated by the satisfactory agreement between the experimental data and numerical results. Prewhirl regulation with IGVs can significantly increase the energy performance and broaden the efficient operation range for the centrifugal pump due to the improvement of flow pattern at the impeller inlet. The prewhirl angle has an obvious impact on pump energy performance, and the maximum amplitudes of pressure fluctuations on the blade leading edge of the pressure and suction sides decrease by 69% and 89%, respectively. The axial distance has a slight impact on pump energy performance, but the maximum amplitudes of pressure fluctuations drop by 35.4% on the blade leading edge of pressure side when the axial distance extends from 280 mm to 460 mm.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.