An insulin-modified frequently sampled intravenous glucose tolerance test (FSIGTT) with minimal model analysis was compared with the glucose clamp in 11 subjects with normal glucose tolerance (NGT), 20 with impaired glucose tolerance (IGT), and 24 with non-insulin-dependent diabetes mellitus (NIDDM). The insulin sensitivity index (SI) was calculated from FSIGTT using 22- and 12-sample protocols (SI(22) and SI(12), respectively). Insulin sensitivity from the clamp was expressed as SI(clamp) and SIP(clamp). Minimal model parameters were similar when calculated with SI(22) and SI(12). SI could not be distinguished from 0 in approximately 50% of diabetic patients with either protocol. SI(22) correlated significantly with SI(clamp) in the whole group (r = 0.62), and in the NGT (r = 0.53), IGT (r = 0.48), and NIDDM (r = 0.41) groups (P < 0.05 for each). SI(12) correlated significantly with SI(clamp) in the whole group (r = 0.55, P < 0.001) and in the NGT (r = 0.53, P = 0.046) and IGT (r = 0.58, P = 0.008) but not NIDDM (r = 0.30, P = 0.085) groups. When SI(22), SI(clamp), and SIP(clamp) were expressed in the same units, SI(22) was 66 +/- 5% (mean +/- SE) and 50 +/- 8% lower than SI(clamp) and SIP(clamp), respectively. Thus, minimal model analysis of the insulin-modified FSIGTT provides estimates of insulin sensitivity that correlate significantly with those from the glucose clamp. The correlation was weaker, however, in NIDDM. The insulin-modified FSIGTT can be used as a simple test for assessment of insulin sensitivity in population studies involving nondiabetic subjects. Additional studies are needed before using this test routinely in patients with NIDDM.
Conventional immunoassays to quantify insulin concentration do not differentiate between insulin and proinsulin. Thus, previous conclusions as to the relationship between the development of hyperglycemia in patients with noninsulin-dependent diabetes mellitus (NIDDM) and pancreatic insulin secretory function may have been confounded by not being able to determine the contribution made by plasma proinsulin to the putative measurements of plasma insulin concentration in these patients. The current study was initiated to address this issue by making specific measurements of plasma insulin, proinsulin, and C-peptide concentrations in 42 individuals: 14 with normal glucose tolerance, 12 with impaired glucose tolerance (IGT), and 16 with NIDDM. The study population was further subdivided into a nonobese (body mass index, < 30 kg/m2) and an obese (body mass index, > 30 kg/m2) group. Mixed meals were given at 0800, 1200, and 1800 h, and blood was removed at 0800 h (before the meal) and at hourly intervals from then until 1600 h. Plasma glucose concentrations throughout the sampling period were slightly, but significantly (P < 0.01), greater in patients with IGT than in normal individuals. Patients with NIDDM had markedly elevated glycemic excursions, greater than either of the other two groups (P < 0.002). Both plasma immunoreactive insulin and C-peptide concentrations from 0800-1600 h were higher (P < 0.002-0.001) in patients with either IGT or NIDDM than in the group with normal glucose tolerance. Although day-long plasma immunoreactive insulin and C-peptide concentrations were higher, on the average, in patients with IGT compared to those with NIDDM, the difference was not statistically significant. Plasma proinsulin concentrations were highest in patients with NIDDM (P < 0.002), lower in those with normal glucose tolerance (P < 0.002), and intermediate in patients with IGT. When the calculated "true" insulin concentration was determined by taking the proinsulin content into consideration, patients with IGT had the highest day-long levels, with the lowest values found in the control population (P < 0.002). Although absolute values varied as a function of obesity, the generalizations outlined above were found in both weight groups. These results show that ambient plasma proinsulin concentrations increase as glucose tolerance declines. However, true plasma insulin concentrations in response to mixed meals remain highest in patients with IGT, lowest in normal individuals, and intermediate in patients with NIDDM. Thus, previous conclusions that absolute day-long plasma insulin concentrations are not lower than normal in patients with NIDDM do not appear to result from an inability to differentiate true insulin from proinsulin.
High density lipoprotein (HDL) kinetics were studied by injecting [3H]apoprotein A-I (apoA-I)/HDL into 12 subjects with normal glucose tolerance and 12 patients with noninsulin-dependent diabetes mellitus (NIDDM). The results indicate that the mean fractional catabolic rate (FCR) of apoA-I/HDL was significantly faster [0.63 +/- 0.07 (+/- SEM) vs. 0.39 +/- 0.02 1/day; P less than 0.001] and the apoA-I/HDL synthetic rate greater (29.4 +/- 2.9 vs. 22.9 +/- 1.3 mg/kg X day; P less than 0.02) in patients with NIDDM than in normal subjects. Furthermore, there were statistically significant inverse relationships between apoA-I/HDL FCR and plasma levels of both HDL cholesterol (r = -0.71; P less than 0.001) and apoA-I (r = -0.63; P less than 0.001). In addition, the increase in apoA-I/HDL FCR was directly related to fasting plasma glucose (r = 0.78; P less than 0.001) and insulin (r = 0.76; P less than 0.001) concentrations. These data support the view that the decrease in plasma HDL cholesterol and apoA-I levels commonly found in patients with noninsulin-dependent diabetes is due to an increase in the catabolic rate of apoA-I/HDL secondary to the defects in carbohydrate metabolism present in these patients.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.