Background: Left bundle branch pacing (LBBP) has been suggested as an alternative means to deliver cardiac resynchronization therapy (CRT). Hypothesis: LBBP may deliver resynchronization therapy along with an advantage over traditional biventricular (BiV) pacing in clinical outcomes. Methods: Heart failure patients who presented LBBB morphology according to Strauss's criteria and received successful CRT procedure were enrolled in the present study. Propensity score matching was applied to match patients into LBBP-CRT group and BiV-CRT group. Then, the electrographic data, the echocardiographic data and New York heart association (NYHA) class were compared between the groups. Results: Twenty-one patients with successful LBBP procedure and another 21 matched patients with successful BiV-CRT procedure were finally enrolled in the study. The QRS duration (QRSd) was narrowed from 167.7 ± 14.9 ms to 111.7 ± 12.3 ms (P < .0001) in the LBBP-CRT group and from 163.6 ± 13.8 ms to 130.1 ± 14.0 ms (P < .0001) in the BiV-CRT group. A trend toward better left ventricular ejection fraction (LVEF) was recorded in the LBBP-CRT group (50.9 ± 10.7% vs 44.4 ± 13.3%, P = .12) compared to that in the BiV-CRT group at the 6-month follow-up. A trend toward better echocardiographic response was documented in patients receiving LBBP-CRT procedure (90.5% vs 80.9%, P = .43) and more super CRT response was documented in the LBBP-CRT group (80.9% vs 57.1%, P = .09) compared to that in the BiV-CRT group. Conclusions: LBBP-CRT can dramatically improve the electrical synchrony in heart failure patients with LBBB. Meanwhile, compared with the traditional BiV-CRT, it has Jincun Guo and Linlin Li contributed equally to this work.
Aim: The aim of this study is to assess if left bundle branch pacing (LBBP) can preserve physiological cardiac synchrony and deliver favorable hemodynamic effects.Methods: Consecutive patients undergoing dual chamber pacemaker implantation for sick sinus syndrome (SSS) and a normal cardiac function with a narrow QRS complex were recruited for the study. Electrocardiogram and echocardiographic examinations were performed during ventricular pacing-on and native-conduction modes. The QRS duration (QRSd), systolic dyssynchrony index (SDI), and the standard deviation of time-to-peak contraction velocity in left ventricular (LV) 12 segments (Tsd-12-LV) were measured to evaluate LV synchrony. The stroke volume (SV) and the degree of atrioventricular valvular regurgitation were also assessed.Results: A total of 40 patients underwent LBBP, while another 38 patients underwent right ventricular septum pacing (RVSP) as control group. Baseline characteristics were similar between the two groups. With LBBP, the paced QRSd was slightly wider than the intrinsic QRSd (101.03 ± 8.79 ms vs 91.06 ± 14.17 ms, P < .0001) while the LV mechanical synchrony during LBBP pacing mode was similar to that of native-conduction mode (SDI, 3.14 ± 2.49 vs 2.70 ± 1.68, P = 0.129; Tsd-12-LV, 26.43 ± 15.55 vs 25.61 ± 16.07, P = .671) in the LBBP group. The LV synchrony in the LBBP group was superior to the RVSP group significantly. No significant differences in SV (64.08 ± 16.97 mL vs 65.45 ± 18.68 mL, P = .241) or the degree of atrioventricular valvular regurgitation were noted between LBBP capture and native-conduction modes. Conclusion: LBBP could preserve satisfactory LV synchrony and result in favorable hemodynamic effects. K E Y W O R D S cardiac mechanical synchrony, echocardiography, hemodynamic effects, left bundle branch pacing, physiological pacing, right ventricular septum pacing, sick sinus syndrome ---
Introduction: Left bundle branch pacing (LBBP) is a promising new method for patients with pacing indications. This study aims to evaluate the safety and feasibility of LBBP in a relatively longer time span. Methods and Results: A total of 164 patients were recruited for LBBP in this study. Among these patients, 148 patients had pacing indications due to symptomatic bradycardia while the other 16 patients had indications for cardiac resynchronization therapy (CRT). LBBP was successful in 89.0% (146/164) of all recruited patients.Intracardiac and surface electrographic parameters and image data were documented during the LBBP procedure. The mean paced QRS duration (pQRSD) and the mean stimulus to left ventricular activation time (stim-LVAT) was 106.0 ± 12.9 ms and 64.4 ± 13.7 ms respectively. Left bundle branch (LBB) potentials were recorded in 89 patients. Forty-three of whom had sick sinus syndrome (SSS), and 46 had atrioventricular block (AVB). The presence of LBB potential was more common in patients with SSS (82.7% vs 57.5%, P = .002). No significant differences in pQRSD, stim-LVAT, or capture threshold were detected between patient groups with or without LBB potential. Patients were followed up at 1 month, 3 months, 6 months, and 1 year after the procedure. Pacing parameters and the echocardiographic data remained stable within a mean follow-up period of 8.6 ± 4.3 months. No serious complication caused by this procedure was found in this study.Conclusions: Successful LBBP carried an aspect of short pQRSD and stim-LVAT while the LBB potential was not the prerequisite and necessary feature. The LBBP procedure had a high success rate with satisfied and stable lead parameters during short and intermediate-term observations. K E Y W O R D S feasibility, intermediate-term, left bundle branch pacing, left bundle branch potential, safety ---This is an open access article under the terms of the Creative Commons Attribution License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.Pacing-QRS duration (ms) 106.0 ± 12.9Stim-LVAT (ms) 64.4 ± 13.7Abbreviations: AVB, atrioventricular block; ECG, electrocardiogram; CLBBB, complete left bundle branch block; CRBBB, complete right bundle branch; CRT, cardiac resynchronization therapy; LBB, left bundle branch; LBBP, left bundle branch pacing; PVI, potential to ventricular interval; stim-LVAT, stimulus to left ventricular activation time. 1474| GUO ET AL.
Background: Left bundle branch pacing (LBBP) has emerged as a promising pacing modality for preventing pacing induced cardiomyopathy in patients complicated with conduction abnormalities (CAs) after prosthetic valve (PV) implantation. Objective: The present study aimed to evaluate the safety and feasibility of LBBP in this patient population. Methods: LBBP was attempted in 20 patients complicated with atrioventricular block after PV implantation. Surface, intracardiac electrical measurements, and echocardiographic data were documented. Lead parameters and complications were routinely tracked at implantation and each follow-up visit. Results: LBBP was successful in 90% (18/20) participants. The paced QRS duration and the stimulus to left ventricular activation time were 106.8 ± 6.8 ms and 65.5 ± 5.4 ms, respectively. Left bundle branch (LBB) potential was recorded in 61.1% (11/18) patients who succeeded in LBBP. During the procedure, the mean unipolar myocardium capture threshold was 0.51 ± 0.15 V@0.4 ms while the unipolar bundle capture threshold was 0.84 ± 0.51 V@0.4 ms. The mean fluoroscopic exposure time and the radiation dose were 13.0 ± 9.2 min and 81.7 ± 8.3 mGy, respectively. The average follow-up period was 10.4 ± 5.9 months (range 3-23 months). Pacing parameters remained stable and no significant lead-related complications occurred during the whole observation period. Conclusions: LBBP was safe and feasible in patients with PVs. Acceptable and stable pacing parameters could be expected during the procedure and the follow-ups. K E Y W O R D S left bundle branch pacing, permanent pacemaker implantation, physiological pacing, prosthetic valves 1 | INTRODUCTION Atrioventricular heart block is a common complication in patients received prosthetic valve (PV) implantation. The incidences ranging Jincun Guo and Linlin Li contributed equally to this work.
Background: Right ventricular (RV) myocardial work (RVMW) is the latest method used to assess RV function. To date, correlations among RVMW indices and RV systolic and diastolic functions have not been studied.Methods: A total of 106 healthy volunteers (median age, 34 years; 46% male) were prospectively enrolled. RVMW indices were measured using the RV pressure-strain loop using specific software. The correlations among RVMW indices and other RV functions were analyzed. Results: During the multivariate analysis, the RV global work index (RVGWI) was significantly correlated with RV global longitudinal strain (RV GLS) (p < .0001), pulmonary systolic artery pressure (PASP) (p < .0001), and tricuspid annular (TA) plane systolic excursion (TAPSE) (p = .036). RV global constructive work (RVGCW) was correlated with RV GLS (p < .0001) and PASP (p < .0001). RV global wasted work (RVGWW) was correlated with RV GLS (p = .008) and TA isovolumetric acceleration (TA IVA) (p = .008). RV global work efficiency (RVGWE) was correlated with RV GLS (p < .0001) and tissue Doppler (TD) RV myocardial performance index (TD RMPI) (p = .043). Conclusion: RVMW indices showed good correlations with RV myocardial systolic function.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.