Formononetin is one of the main components of red clover plants, and is considered as a typical phytoestrogen. This study further investigated that formononetin inactivated IGF1/IGF1R-PI3K/Akt pathways and decreased cyclin D1 mRNA and protein expression in human breast cancer cells in vitro and in vivo. MCF-7 cells were treated with different concentrations of formononetin. The proliferation of the cells treated with formononetin was tested by MTT assay. The cell cycle in the treated cells was examined by flow cytometry. The levels of p-IGF-1 R, p-Akt, and cyclin D1 protein expression and cyclin D1 mRNA expression in the treated cells were determined by Western blot and RT-PCR, respectively. In addition, the antitumor activity of formononetin was evaluated in nude mice bearing orthotopic tumor implants. Compared with the control, formononetin inhibited the proliferation of MCF-7 cells and effectively induced cell cycle arrest. The levels of p-IGF-1 R, p-Akt, cyclin D1 protein expression, and cyclin D1 mRNA expression were also downregulated. On the other hand, formononetin also prevented the tumor growth of human breast cancer cells in nude mouse xenografts. These results show that formononetin causes cell cycle arrest at the G0/G1 phase by inactivating IGF1/IGF1R-PI3K/Akt pathways and decreasing cyclin D1 mRNA and protein expression, indicating the use of formononetin in the prevention of breast cancer carcinogenesis.
Aseptic loosening (AL) caused by wear particles released from implant surfaces is one of the main causes for the failure of artificial joints, which is initiated by macrophage inflammatory responses.
Digital microfluidic (DMF) sensors integrated with circuit systems have been applied to a broad range of applications including biology, medicine, and chemistry. Compared with the conventional microfluidic devices that require extra liquid as a carrier and a complex pumping system to operate, DMF is an ideal platform for ion-selective sensing as it enables the droplet operation in a discrete, accurate, and automatic way. However, it is quite rare that DMF platform is utilized for the ion-selective detection. In this paper, we report an integrated DMF system which combines DMF and ionselective sensing for facile blending of multiple ions, and detection of targeted primary ion. The platform is fabricated through an additive manufacturing method, together with the real-time droplet's motion monitoring feedback system. Thus, the fabricated system demonstrates controlled droplet manipulation ability including droplet actuation, mixing, and speed control. Targeted primary ion is selectively detected under concentration range from 10 −6 to 1 M. The interference study with blended ions has been investigated through on-chip ion selective membranes.
Background: Opioid titration is necessary to achieve rapid, safe pain relief. Medication can be administered via patient-controlled analgesia (PCA) or by a healthcare provider (non-PCA). We evaluated the efficacy of intravenous PCA versus non-PCA hydromorphone titration for severe cancer pain (≥7 at rest on the 11-point numeric rating scale [NRS]). Patients and Methods: Patients with severe cancer pain were randomized 1:1 to PCA or non-PCA titration, stratified by opioid-tolerant or opioid-naïve status. The PCA pump was set to no continuous dose, with a hydromorphone bolus dose 10% to 20% of the total previous 24-hour equianalgesic (for opioid-tolerant patients) or 0.5 mg (for opioid-naïve patients). For the non-PCA group, the initial hydromorphone bolus dose was identical to that in the PCA group, with the subsequent dose increased by 50% to 100% (for NRS unchanged or increased) or repeated at the current dose (for NRS 4–6). Hydromorphone delivery was initiated every 15 minutes (for NRS ≥4) or as needed (for NRS ≤3). The primary endpoint was time to successful titration (TST; time from first hydromorphone dose to first occurrence of NRS ≤3 in 2 consecutive 15-minute intervals). Results: Among 214 patients (PCA, n=106; non-PCA, n=108), median TSTs (95% CI) were 0.50 hours (0.25–0.50) and 0.79 hours (0.50–1.42) for the PCA and non-PCA groups, respectively (hazard ratio [HR], 1.64; 95% CI, 1.23–2.17; P=.001). TSTs in opioid-tolerant patients were 0.50 hours (0.25–0.75) and 1.00 hours (0.50–2.00) for the PCA and non-PCA groups, respectively (HR, 1.92; 95% CI, 1.32–2.78; P=.003); in opioid-naive patients, TST was not significantly different for the PCA versus non-PCA groups (HR, 1.35; 95% CI, 0.88–2.04; P=.162). Pain score (median NRS; interquartile range) over 24 hours was significantly lower in the PCA group (2.80; 2.15–3.22) than in the non-PCA group (3.00; 2.47–3.53; P=.020). PCA administration produces significantly higher patient satisfaction with pain control than non-PCA administration (P<.001). Conclusions: Intravenous hydromorphone titration for severe cancer pain was achieved more effectively with PCA than with non-PCA administration.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.