Objective To compare myocardial blood flow (MBF) and myocardial flow reserve (MFR) estimates from 82Rb PET data using ten software packages (SPs): Carimas, Corridor4DM, FlowQuant, HOQUTO, ImagenQ, MunichHeart, PMOD, QPET, syngo MBF, and UW-QPP. Background It is unknown how MBF and MFR values from existing SPs agree for 82Rb PET. Methods Rest and stress 82Rb PET scans of 48 patients with suspected or known coronary artery disease (CAD) were analyzed in 10 centers. Each center used one of the 10 SPs to analyze global and regional MBF using the different kinetic models implemented. Values were considered to agree if they simultaneously had an intraclass correlation coefficient (ICC) > 0.75 and a difference < 20% of the median across all programs. Results The most common model evaluated was the one-tissue compartment model (1TCM) by Lortie et al. (2007). MBF values from seven of the eight software packages implementing this model agreed best (Carimas, Corridor4DM, FlowQuant, PMOD, QPET, syngoMBF, and UW-QPP). Values from two other models (El Fakhri et al. in Corridor4DM and Alessio et al. in UW-QPP) also agreed well, with occasional differences. The MBF results from other models (Sitek et al. 1TCM in Corridor4DM, Katoh et al. 1TCM in HOQUTO, Herrero et al. 2TCM in PMOD, Yoshida et al. retention in ImagenQ, and Lautamäki et al. retention in MunichHeart) were less in agreement with Lortie 1TCM values. Conclusions SPs using the same kinetic model, as described in Lortie et al. (2007), provided consistent results in measuring global and regional MBF values, suggesting they may be used interchangeably to process data acquired with a common imaging protocol.
Routine quantification of myocardial blood flow (MBF) requires robust and reproducible processing of dynamic image series. The goal of this study was to evaluate the reproducibility of 3 highly automated software programs commonly used for absolute MBF and flow reserve (stress/rest MBF) assessment with 82 Rb PET imaging. Methods: Dynamic rest and stress 82 Rb PET scans were selected in 30 sequential patient studies performed at 3 separate institutions using 3 different 3-dimensional PET/CT scanners. All 90 scans were processed with 3 different MBF quantifi-cation programs, using the same 1-tissue-compartment model. Global (left ventricle) and regional (left anterior descending, left circumflex, and right coronary arteries) MBF and flow reserve were compared among programs using correlation and Bland-Altman analyses. Results: All scans were processed successfully by the 3 programs, with minimal operator interactions. Global and regional correlations of MBF and flow reserve all had an R 2 of at least 0.92. There was no significant difference in flow values at rest (P 5 0.68), stress (P 5 0.14), or reserve (P 5 0.35) among the 3 programs. Bland-Altman coefficients of reproducibility (1.96 · SD) averaged 0.26 for MBF and 0.29 for flow reserve differences among programs. Average pairwise differences were all less than 10%, indicating good reproducibility for MBF quantification. Global and regional SD from the line of perfect agreement averaged 0.15 and 0.17 mL/min/g, respectively, for MBF, compared with 0.22 and 0.26, respectively, for flow reserve. Conclusion: The 1-tissue-compartment model of 82 Rb tracer kinetics is a reproducible method for quantification of MBF and flow reserve with 3-dimensional PET/CT imaging. Absol ute quantification of myocardial blood flow (MBF) at stress and rest with dynamic PET imaging is an important tool for clinicians and provides information complementary to relative myocardial perfusion imaging (1-3). With standard list-mode acquisition and fast image reconstruction , dynamic, gated, and standard static perfusion images can be obtained with a single injection of the radiopharmaceutical and without additional imaging time. Automated image analysis tools are required for reliable and robust clinical use of dynamic data for MBF quantification (4). The performance of several such software programs for MBF quan-tification has been reported recently (5-9), each of which uses different tracers and methods of segmenting and sampling the left ventricular myocardium and blood-pool activity to obtain input curves. Although each of these tools greatly simplifies MBF quantification, uses the same tracer kinetic model for 82 Rb-rubidium (10), and has been validated individually , the effect of different model implementations has not been characterized. Previous studies have compared different tracer kinetic models and implementations for 13 N-ammonia (11,12) but not for 82 Rb-rubidium and in particular not for 3-dimensional (3D)-mode PET, which is the current standard technology. We aimed to comp...
The standard mammogram form (SMF) representation of an x-ray mammogram is a standardized, quantitative representation of the breast from which the volume of non-fat tissue and breast density can be easily estimated, both of which are of significant interest in determining breast cancer risk. Previous theoretical analysis of SMF had suggested that a complete and substantial set of calibration data (such as mAs and kVp) would be needed to generate realistic breast composition measures and yet there are many interesting trials that have retrospectively collected images with no calibration data. The main contribution of this paper is to revisit our previous theoretical analysis of SMF with respect to errors in the calibration data and to show how and why that theoretical analysis did not match the results from the practical implementations of SMF. In particular, we show how by estimating breast thickness for every image we are, effectively, compensating for any errors in the calibration data. To illustrate our findings, the current implementation of SMF (version 2.2beta) was run over 4028 digitized film-screen mammograms taken from six sites over the years 1988-2002 with and without using the known calibration data. Results show that the SMF implementation running without any calibration data at all generates results which display a strong relationship with when running with a complete set of calibration data, and, most importantly, to an expert's visual assessment of breast composition using established techniques. SMF shows considerable promise in being of major use in large epidemiological studies related to breast cancer which require the automated analysis of large numbers of films from many years previously where little or no calibration data is available.
Quantitative normal MBF and MFR values averaged for age and sex have been compiled for three commercial pharmacokinetic software packages. The current collection of data consisting of 49 subjects resulted in several statistically significant conclusions that support the need for a software specific, age, and sex-matched database to aid in interpretation of quantitative clinical myocardial perfusion studies.
This study investigated differences in cardiac displacement during adenosine stress versus regadenoson stress in N-ammonia (NH) MP PET/CT scans. In total, 61 myocardial perfusion PET/CT scans were acquired using either adenosine ( = 30) or regadenoson ( = 31) as a stressor. For both groups, cardiac displacement during rest and stress was measured 3-dimensionally, relative to either a fixed reference frame or the previous frame, in each 1-min frame of a list-mode PET acquisition of 25 min. All stress scans were additionally evaluated for the presence of motion artifacts. Also, the tolerability of the agents and the occurrence of side effects were compared between groups. Significantly larger cardiac displacement during stress was detected in the adenosine group than in the regadenoson group, reflected by both maximal cardiac displacement ( = 0.022) and mean cardiac displacement ( = 0.001). The duration of the movement was typically shorter in the regadenoson group. Frames with cardiac displacement of at least 5 mm were observed nearly twice as frequently when adenosine was used instead of regadenoson. The displacement during regadenoson stress is of lower amplitude and shorter duration than that during adenosine stress and may therefore contribute to a lower incidence of motion artifacts on PET/CT scans.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.