(1) Coronary CT angiography (CCTA) scans with shortened contrast medium injection duration and late triggering are feasible with a 16-cm wide-detector CT system (2) Compared with the conventional CCTA with 10 s contrast injection duration, the new contrast injection protocol of using shortened injection duration (to 8 s) and late triggering reduces contrast dose to 36.2 ml, while maintaining adequate enhancement in vessels and reducing contrast-related artifacts.
Purpose: To develop a deep-learning system for automatic osteoporotic vertebral compression fractures (OVCF) detection at the thoracolumbar junction using low-dose computed tomography (CT) images.
Materials and methods: 500 individuals were enrolled in this retrospective study, including 270 normal and 230 OVCF cases. The cases were divided into the training, validation, and test sets in the ratio of 6:2:2. First, a localization model using Faster R-CNN was trained to identify and locate the target thoracolumbar junction, then a 3D AnatomyNet model was trained to finely segment the target vertebrae in the localized image. Finally, 3D DenseNet model was applied for detecting OVCF on target vertebrae. Manual annotation by experienced radiologists and a clinically made diagnosis of OVCF were used as the gold standards. The performance of the detecting system was evaluated through the area under the curve (AUC) for receiver operating characteristic (ROC) analysis, sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV).
Results Our automated segmentation method achieved a mean Dice coefficient of 0.95 for vertebral bodies (T12-L2) segmentation on the testing dataset, with dice coefficients greater than 0.9 accounting for 96.6%. For the diagnostic performance of our system for OVCF, the AUC, sensitivity, specificity, PPV and NPV for the four-fold cross-validation on the testing dataset were 98.1%, 95.7%, 92.6%, 91.7% and 96.2%, respectively.
Conclusions A deep-learning system has been developed to automatically segment vertebral bodies and accurately detect OVCF using low-dose CT.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.