Strawberry cultivation is highly dependent on environmental parameters and energy during the winter. Two gothic greenhouses with different glazing material combinations, polyolefin–thermal screen (PoTS) and polyolefin–thermal screen–polyethylene (PoTSPe), were used for strawberry cultivation. The energy-saving capabilities of the two configurations and their impact on the microclimates of the greenhouses were investigated. The temperature, relative humidity, vapor pressure deficit, leaf temperature, carbon dioxide concentration and solar radiation over the experimental period in the PoTS greenhouse were 13.0 ± 2.3°C, 75.8 ± 6.5%, 0.4 ± 0.1 kPa, 13.6 ± 1.7 °C, and 168.8 ± 82.3W/m2, respectively, whereas those of the PoTSPe condition were 13.1 ± 2.3 °C, 80.0 ± 5.7%, 0.3 ± 0.1 kPa, 13.5 ± 1.6 °C, and 183.1 ± 90.5 W/m2. The mean fuel consumption by the PoTS and PoTSPe greenhouses were 5.5 and 3.5 L, respectively. The performance analysis shows that both greenhouses were able to maintain the environmental parameters and leaf temperature within the recommended ranges, although more energy was consumed in the PoTS. More yield was obtained in the PoTS greenhouse, however, not significantly different from PoTSPe yield.
In this work, we proposed a Building Energy Simulation (BES) dynamic climatic model of greenhouses by utilizing Transient System Simulation (TRNSYS 18) software to study the effect of use of different thermal screen materials and control strategies of thermal screens on heat energy requirement of greenhouses. Thermal properties of the most common greenhouse thermal screens were measured and used in the BES model. Nash-Sutcliffe efficiency coefficients of 0.84 and 0.78 showed good agreement between the computed and experimental results, thus the proposed model appears to be appropriate for performing greenhouse thermal simulations. The proposed model was used to evaluate the effects of different thermal screens including; Polyester, Luxous, Tempa, and Multi-layers, as well as to evaluate control strategies of greenhouse thermal screens, subjected to Daegu city, (latitude 35.53 °N, longitude 128.36 °E) South Korea winter season weather conditions. Obtained results show that the heating requirement of greenhouses with multi-layer night thermal screens was 20%, 5.4%, and 13.5%, less than the Polyester, Luxous, and Tempa screens respectively. Thus, our experiments confirm that the use of multi-layered thermal screen can reduce greenhouse heat energy requirement. Furthermore, screen-control with outside solar radiation at an optimum setpoint of 60 W·m−2 significantly influences the greenhouse’s energy conservation capacity, as it exhibited 699.5 MJ · m−2, the least energy demand of all strategies tested. Moreover, the proposed model allows dynamic simulation of greenhouse systems and enables researchers and farmers to evaluate different screens and screen control strategies that suit their investment capabilities and local weather conditions.
In this study, we propose a building energy simulation model of a multi-span greenhouse using a transient system simulation program to simulate greenhouse microenvironments. The proposed model allows daily and seasonal control of screens, roof vents, and heating setpoints according to crop needs. The proposed model was used to investigate the effect of different thermal screens, natural ventilation, and heating setpoint controls on annual and maximum heating loads of a greenhouse. The experiments and winter season weather conditions of greenhouses in Taean Gun (latitude 36.88° N, longitude 126.24° E, elevation 45 m) Chungcheongnam-do, South Korea was used for validation of our model. Nash–Sutcliffe efficiency coefficients of 0.87 and 0.71 showed good correlation between the computed and experimental results; thus, the proposed model is appropriate for performing greenhouse thermal simulations. The results showed that the heating loads of the triple-layered screen were 70% and 40% lower than that of the single-screen and double-screen greenhouses, respectively. Moreover, the maximum heating loads without a screen and for single-, double-, and the triple-layered screens were 0.65, 0.46, 0.41, and 0.34 MJ m−2, respectively. The analysis of different screens showed that Ph-77 (shading screen) combined with Ph-super (thermal screen) had the least heating requirements. The heating setpoint analysis predicted that using the designed day- and nighttime heating control setpoints can result in 3%, 15%, 14%, 15%, and 40% less heating load than when using the fixed value temperature control for November, December, January, February, and March, respectively.
Greenhouse farmers often use thermal screens to reduce greenhouse heating expenses during the winter, and for shade during hot, sunny days in the summer, as it is an inexpensive solution to temperature control relative to other available options. However, accurate measurements of their emitted and absorbed radiations are important for the selection of suitable screens that offer maximum performance. Material's ability to save energy is highly dependent on these properties. Limited studies have investigated the measurement of these properties under natural conditions, but they are only applicable to materials having partial porosities. In this work, we describe a new radiation balance method for determining emissive power and absorptive capacity, as well as reflectivity, transmissivity and emissivity of materials having complete and partial transparency by using pyrgeometer and net radiometer. In this study, four materials with zero porosity, were tested. The emissivity value of PE, LD-13, LD-15 and PH-20 was 0.439±0.020, 0.460±0.010, 0.454±0.004, and 0.499±0.006, respectively. All tested samples showed high emitted radiation as compared to absorbed radiation.
This study proposes a building energy simulation (BES) model of an air-to-water heat pump (AWHP) system integrated with a multi-span greenhouse using the TRNSYS-18 program. The proposed BES model was validated using an experimental AWHP and a multi-span greenhouse installed in Kyungpook National University, Daegu, South Korea (latitude 35.53° N, longitude 128.36° E, elevation 48 m). Three AWHPs and a water storage tank were used to fulfill the heat energy requirement of the three-span greenhouse with 391.6 m2 of floor area. The model was validated by comparing the following experimental and simulated results, namely, the internal greenhouse temperature, the heating load of the greenhouse, heat supply from the water storage tank to the greenhouse, heat pumps’ output water temperature, power used by the heat pumps, coefficient of performance (COP) of the heat pump, and water storage tank temperature. The BES model’s performance was evaluated by calculating the root mean square error (RMSE) and the Nash–Sutcliffe efficiency (NSE) coefficient of validation results. The overall results correlated well with the experimental and simulated results and encouraged adopting the BES model. The average calculated COP of the AWHP was 2.2 when the outside temperature was as low as −13 °C. The proposed model was designed simply, and detailed information of each step is provided to make it easy to use for engineers, researchers, and consultants.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.