e analysed the CT scans and radiographs of 76 vertebrae in 49 patients who underwent vertebroplasty for painful osteoporotic compression fractures. Leaks of cement were classified into three types: those via the basivertebral vein (type B), via the segmental vein (type S), and through a cortical defect (type C). More leaks were identified on CT scans than on radiographs by a factor of 1.5 (74/49). Most type-B (93%) and type-S (86%) leaks were missed or underestimated on a lateral radiograph which is usually the only view used during the injection of cement. Of the leaks into the spinal canal, only 7% (2/28) were correctly identified on radiographs. The areas on lateral radiographs where this type of leak may be observed were divided into four zones, and their diagnostic value in predicting a leak into the spinal canal was evaluated. The results showed that cement in the neural foramina had the highest positive predictive value (86%).
BackgroundThe purpose of this study was to evaluate the screw-home movement at the tibiofemoral joint during normal gait by utilizing the 3-dimensional motion capture technique.MethodsFifteen young males and fifteen young females (total 60 knee joints) who had no history of musculoskeletal disease or a particular gait problem were included in this study. Two more markers were attached to the subject in addition to the Helen-Hayes marker set. Thus, two virtual planes, femoral coronal plane (Pf) and tibial coronal plane (Pt), were created by Skeletal Builder software. This study measured the 3-dimensional knee joint movement in the sagittal, coronal, and transverse planes of these two virtual planes (Pf and Pt) during normal gait.ResultsWith respect to kinematics and kinetics, both males and females showed normal adult gait patterns, and the mean difference in the temporal gait parameters was not statistically significant (p > 0.05). In the transverse plane, the screw-home movement occurred as expected during the pre-swing phase and the late-swing phase at an angle of about 17°. However, the tibia rotated externally with respect to the femur, rather than internally, while the knee joint started to flex during the loading response (paradoxical screw-home movement), and the angle was 6°.ConclusionsParadoxical screw-home movement may be an important mechanism that provides stability to the knee joint during the remaining stance phase. Obtaining the kinematic values of the knee joint during gait can be useful in diagnosing and treating the pathological knee joints.
BackgroundWe analyzed the extent of the comminution in the acetabular weight-bearing area, the clinical and radiographic results, and the complications after a minimum 2-year follow-up of the modified Stoppa approach for the treatment of acetabular fractures, and we attempted to evaluate the efficacy of the operative technique.MethodsAll of the 22 patients, who needed the anterior approach for the treatment of acetabular fractures at our hospital from November 2007 to November 2010, were subjected to surgery via the modified Stoppa approach. Fracture pattern, operative time, blood loss during the operation, quality of reduction, number of bony fragments in the acetabular weight-bearing area, and postoperative complications were assessed by retrospectively analyzing the medical records and the radiographic examinations. The results after the operation were analyzed based on the criteria of Matta.ResultsThe clinical results were excellent in 3 cases, good in 13 cases, and poor in 4 cases, while the radiographic results were excellent in 5 cases, good in 13 cases, and poor in 2 cases. Although the quality of reduction and the clinical results according to the extent of comminution were statistically significant (p = 0.03 and p = 0.04, respectively), the radiographic results were not statistically significant (p = 0.74).ConclusionsIt can be concluded that the modified Stoppa approach could be used as an alternative to the classic ilioinguinal approach. In addition, comminution of the acetabular fracture was an important factor causing non-anatomic reduction and finally unsatisfactory clinical results.
Despite the theoretical improvement in the fracture toughness of a polyethylene-alumina composite liner, a relatively high rate of catastrophic ceramic bearing surface failure was still observed at the time of short-term follow-up. This finding prompted us to discontinue the use of this type of alumina bearing design.
Based on the significant differences in the ratio of the contralateral side, plate osteosynthesis resulted in a more excellent extent of restoration to the conditions prior to the injury. Nevertheless, such significant differences in the restoration of the bow had no effect on the final clinical outcome. If the indication is properly selected, our results suggested intramedullary nailing can be acceptable and effective treatment options for fractures in both forearm bones.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.