We present ultra high speed optical coherence tomography (OCT) with multi-megahertz line rates and investigate the achievable image quality. The presented system is a swept source OCT setup using a Fourier domain mode locked (FDML) laser. Three different FDML-based swept laser sources with sweep rates of 1, 2.6 and 5.2MHz are compared. Imaging with 4 spots in parallel quadruples the effective speed, enabling depth scan rates as high as 20.8 million lines per second. Each setup provides at least 98dB sensitivity and approximately 10microm resolution in tissue. High quality 2D and 3D imaging of biological samples is demonstrated at full scan speed. A discussion about how to best specify OCT imaging speed is included. The connection between voxel rate, line rate, frame rate and hardware performance of the OCT setup such as sample rate, analog bandwidth, coherence length, acquisition dead-time and scanner duty cycle is provided. Finally, suitable averaging protocols to further increase image quality are discussed.
We describe a novel buffering technique for increasing the A-scan rate of swept source optical coherence tomography (SSOCT) systems employing low duty cycle swept source lasers. This technique differs from previously reported buffering techniques in that it employs a fast optical switch, capable of switching in 60 ns, instead of a fused fiber coupler at the end of the buffering stage, and is therefore appreciably more power efficient. The use of the switch also eliminates patient exposure to light that is not used for imaging that occurs at the end of the laser sweep, thereby increasing the system sensitivity. We also describe how careful management of polarization can remove undesirable artifacts due to polarization mode dispersion. In addition, we demonstrate how numerical compensation techniques can be used to modify the signal from a Mach-Zehnder interferometer (MZI) clock obtained from the original sweep to recalibrate the buffered sweep, thereby reducing the complexity of systems employing lasers with integrated MZI clocks. Combining these methods, we constructed an SSOCT system employing an Axsun technologies laser with a sweep rate of 100kHz and 6dB imaging range of 5.5mm. The sweep rate was doubled with sweep buffering to 200 kHz, and the imaging depth was extended to 9 mm using coherence revival. We demonstrated the feasibility of this system by acquiring images of the anterior segments and retinas of healthy human volunteers.
During the summer of 1957 a study of the small metazoans (meiofauna), based on a series of Phleger core samples, was undertaken at three stations in Buzzards Bay, Massachusetts. The number of animals ranged from 1.69 x 105 to 1.86 x 106/m2, the dry weights varied from approximately 100 to 600 mg/m2. The nematodes and kinorhynchs, which comprised between 89 and 99% of the total mieofauna, were studied in detail. The sandy localities (stations P and J) were characterized by a number of nematodes restricted to this habitat, particularly by three representatives of the genus Odontophora and by all representatives of the genus Leptonemella. The locality rich in fine deposits (station R) was characterized by the relative abundance of several nematodes, particularly of Terschellingia longicaudata, and the three kinorhynch species. It was possible to recognize an Odontophora‐Leptonemella community in the sandy habitats, and a Terschellingia longicaudata‐Trachydemus mainensis (kinorhynch) community in the silty habitat, the former being equivalent to the Ampelisca community, the latter to the Nucula proxima‐Nephthys incisa community described for the macrofauna in the same area. However, these “communities” can also be considered as two ecological groups of species, the former dependent on the presence of sand, the latter on that of fine deposits, which actually live side by side, forming an intricate meshwork of faunal combinations. Each combination is determined by the relative amounts of sand and fine deposits present. The uniformity of the nematode fauna within each station was greater than that between two different stations. Most important in determining the degree of faunal uniformity between paired samples is the similarity in their silt‐clay content. However, other mechanical factors also play a role. An analysis of the total species composition of the nematode fauna revealed that Terschellingia longicaudata was the most abundant species at station R, whereas at the stations P and J there were three or four equally dominant species. This is interpreted as indicating a splitting up of the sandy habitat into subhabitats. The simultaneous occurrence of closely related species in this environment further supports the conjecture. The distribution of “buccal types” amongst nematodes is correlated with the distribution of sediments.
In a crude fashion it can be said that metabolizable energy (M) is partitioned into metabolic work, paid for by 'oxidations' (R), and 'assimilation', i.e. production (P), so that M = R+P. However, a fraction of R is required to meet the expenses of production and if these expenses represent, Joule for Joule, a constant proportion of the amount produced, then Rt = Rm+cP, where Rt = total metabolic expenditures, Rm = metabolic expenditures for maintaining the non-producing organism, and cP = Rp = metabolic expenditures connected with the processes of production. The partitioning of metabolizable energy into R and P as well as into Rm and Rp may vary depending on the phylogeny and life-history of the species concerned and on ecological circumstances. Thus selection is expected to act on both ratios, R/P and Rm/Rp. By comparing the ratios P/(P+Rp) (the apparent efficiency of production) and Rp/P (the apparent metabolic cost of production) in different types of organisms, one finds that a value of P/(P+Rp) = 0.75, equal to 75% efficiency, 10 mgdbm/mmol ATP, and 16 mumolO2/mg dbm (when I mg identical to 22 J), can be used as a 'consensus value' for the average efficiency, or cost, of the transformation of metabolizable energy into production in a wide range of organisms, from bacteria to mammals. This value corresponds to about three times the theoretical cost of synthesizing the same amount of tissue on the basis of known biochemical principles. The reasons why the empirical costs of production are higher than the theoretical costs of synthesis by what appears to be a common factor may be quite different in bacteria, small ectothermic and large endothermic organisms. Deviations from the consensus value may be due to differences in energy density of the nutrients assimilated and the tissues synthesized. Further complications arise because of interactions between P, Rp, and Rm. In microorganisms the existence of a constant and a variable component of maintenance metabolism has been postulated, the latter decreasing with increasing rate of production. In small ectothermic metazoans, on the other hand, the nonlinear relationship between growth metabolism and growth rate has led to the speculation that above a critical value of Pg certain energy consuming functions of maintenance are suppressed and the energy thus gained used for fuelling growth processes. There is some evidence that, at least in ectothermic metazoans, the apparent cost of growth decreases with the rate of growth, reaching a low plateau of about 10 mumolO2/mgdbm at growth rates exceeding about 8 mgdbm/g/h.(ABSTRACT TRUNCATED AT 400 WORDS)
Abstract:We analyze the benefits and problems of in vivo optical coherence tomography (OCT) imaging of the human retina at A-scan rates in excess of 1 MHz, using a 1050 nm Fourier-domain mode-locked (FDML) laser. Different scanning strategies enabled by MHz OCT line rates are investigated, and a simple multi-volume data processing approach is presented. In-vivo OCT of the human ocular fundus is performed at different axial scan rates of up to 6.7 MHz. High quality non-mydriatic retinal imaging over an ultra-wide field is achieved by a combination of several key improvements compared to previous setups. For the FDML laser, long coherence lengths and 72 nm wavelength tuning range are achieved using a chirped fiber Bragg grating in a laser cavity at 419.1 kHz fundamental tuning rate. Very large data sets can be acquired with sustained data transfer from the data acquisition card to host computer memory, enabling high-quality averaging of many frames and of multiple aligned data sets. Three imaging modes are investigated: Alignment and averaging of 24 data sets at 1.68 MHz axial line rate, ultra-dense transverse sampling at 3.35 MHz line rate, and dual-beam imaging with two laser spots on the retina at an effective line rate of 6.7 MHz. 58. R. Huber, D. C. Adler, V. J. Srinivasan, and J. G. Fujimoto, "Fourier domain mode locking at 1050 nm for ultrahigh-speed optical coherence tomography of the human retina at 236,000 axial scans per second," Opt. Lett. ©2013 Optical Society of America
We present a 1300 nm OCT system for volumetric real-time live OCT acquisition and visualization at 1 billion volume elements per second. All technological challenges and problems associated with such high scanning speed are discussed in detail as well as the solutions. In one configuration, the system acquires, processes and visualizes 26 volumes per second where each volume consists of 320 x 320 depth scans and each depth scan has 400 usable pixels. This is the fastest real-time OCT to date in terms of voxel rate. A 51 Hz volume rate is realized with half the frame number. In both configurations the speed can be sustained indefinitely. The OCT system uses a 1310 nm Fourier domain mode locked (FDML) laser operated at 3.2 MHz sweep rate. Data acquisition is performed with two dedicated digitizer cards, each running at 2.5 GS/s, hosted in a single desktop computer. Live real-time data processing and visualization are realized with custom developed software on an NVidia GTX 690 dual graphics processing unit (GPU) card. To evaluate potential future applications of such a system, we present volumetric videos captured at 26 and 51 Hz of planktonic crustaceans and skin.
We demonstrate noninvasive structural and microvascular contrast imaging of different human skin diseases in vivo using an intensity difference analysis of OCT tomograms. The high-speed swept source OCT system operates at 1310 nm with 220 kHz A-scan rate. It provides an extended focus by employing a Bessel beam. The studied lesions were two cases of dermatitis and two cases of basal cell carcinoma. The lesions show characteristic vascular patterns that are significantly different from healthy skin. In case of inflammation, vessels are dilated and perfusion is increased. In case of basal cell carcinoma, the angiogram shows a denser network of unorganized vessels with large vessels close to the skin surface. Those results indicate that assessing vascular changes yields complementary information with important insight into the metabolic demand.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.