The medical profession is increasingly confronted with the epidemic phenomenon of obesity. Its impact on spine surgery is not quite clear. Published data concerning the use of minimally invasive surgery (MIS) in the spine among obese patients is scarce. The purpose of the present retrospective study was to evaluate perioperative as well as postoperative complication rates in MIS fusion of the lumbar spine in obese, overweight and normal patients classified according to their body mass index. Lumbar MIS fusion was performed by means of TLIF procedures and/or posterolateral fusion alone. A laminotomy was performed in patients with spinal stenosis. Of 72 patients, 39 underwent additional laminotomy for spinal stenosis. No differences were registered in respect of the numbers of fused segments or cages. Any harmful event occurring peri-or postoperatively was noted and included in the statistical analysis. No infection at the site of surgery or severe wound healing disorder was encountered. We registered no difference in blood loss, drainage, or the length of the hospital stay between the three BMI groups.We also observed no difference in complication rates between the three groups. This study confirms the low soft tissue damage of minimal access surgery techniques, which is an important type of surgery in obese patients. The smaller approach helps to minimize infections and wound healing disorders. Moreover, deeper regions of wounds are clearly visualized with the aid of tubular retractors.
Minimally invasive lumbar interbody fusion (MILIF) offers potential for reduced operative morbidity and earlier recovery compared with open procedures for patients with degenerative lumbar disorders (DLD). Firm conclusions about advantages of MILIF over open procedures cannot be made because of limited number of large studies of MILIF in a real-world setting. Clinical effectiveness of MILIF in a large, unselected real-world patient population was assessed in this Prospective, monitored, international, multicenter, observational study. Objective: To observe and document short-term recovery after minimally invasive interbody fusion for DLD. Materials and Methods: In a predefined 4-week analysis from this study, experienced surgeons (≥30 MILIF surgeries pre-study) treated patients with DLD by one- or two-level MILIF. The primary study objective was to document patients’ short-term post-interventional recovery (primary objective) including back/leg pain (visual analog scale [VAS]), disability (Oswestry Disability Index [ODI]), health status (EQ-5D) and Patient satisfaction. Results: At 4 weeks, 249 of 252 patients were remaining in the study; the majority received one-level MILIF (83%) and TLIF was the preferred approach (94.8%). For one-level (and two-level) procedures, surgery duration was 128 (182) min, fluoroscopy time 115 (154) sec, and blood-loss 164 (233) mL. Time to first ambulation was 1.3 days and time to study-defined surgery recovery was 3.2 days. Patients reported significantly (P < 0.0001) reduced back pain (VAS: 2.9 vs 6.2), leg pain (VAS: 2.5 vs 5.9), and disability (ODI: 34.5% vs 45.5%), and a significantly (P < 0.0001) improved health status (EQ-5D index: 0.61 vs 0.34; EQ VAS: 65.4 vs 52.9) 4 weeks postoperatively. One adverse event was classified as related to the minimally invasive surgical approach. No deep site infections or deaths were reported. Conclusions: For experienced surgeons, MILIF for DLD demonstrated early benefits (short time to first ambulation, early recovery, high patient satisfaction and improved patient-reported outcomes) and low major perioperative morbidity at 4 weeks postoperatively.
The objective of the study is to assess effectiveness and safety of minimally invasive lumbar interbody fusion (MILIF) for degenerative lumbar disorders (DLD) in daily surgical practice and follow up with patients for one year after surgery.A prospective, multicenter, pragmatic, monitored, international outcome study in patients with DLD causing back/leg pain was conducted (19 centers). Two hundred fifty-two patients received standard of care available in the centers. Patients were included if they were aged >18 years, required one- or two-level lumbar fusion for DLD, and met the criteria for approved device indications. Primary endpoints: time to first ambulation (TFA) and time to surgery recovery (TSR). Secondary endpoints: patient-reported outcomes (PROs)--back and leg pain (visual analog scale), disability (Oswestry Disability Index (ODI)), health status (EQ-5D), fusion rates, reoperation rates, change in pain medication, rehabilitation, return to work, patient satisfaction, and adverse events (AEs). Experienced surgeons (≥30 surgeries pre-study) treated patients with DLD by one- or two-level MILIF and patients were evaluated for one year (NCT01143324).At one year, 92% (233/252) of patients remained in the study. Primary outcomes: TFA, 1.3 ±0.5 days and TSR, 3.2 ±2.0 days. Secondary outcomes: Most patients (83.3%) received one level MILIF; one (two-level) MILIF mean surgery duration, 128 (182) min; fluoroscopy time, 115 (154) sec; blood loss, 164 (233) mL; at one year statistically significant (P<.0001) and clinically meaningful changes from baseline were reported in all PROs--reduced back pain (2.9 ±2.5 vs. 6.2 ±2.3 at intake), reduced leg pain (2.2 ±2.6 vs. 5.9 ±2.8), and ODI (22.4% ± 18.6 vs. 45.3% ± 15.3), as well as health-related quality of life (EQ-5D index: 0.71 ±0.28 vs. 0.34 ±0.32). More of the professional workers were working at one year than those prior to surgery (70.3% vs. 55.2%). Three AEs and one serious AE were considered procedure-related; there were no deep site infections or deaths.This is the first study evaluating MILIF for treatment of DLD in daily clinical practice. Clinically significant improvements were observed in all endpoints. Short-term post-surgery improvements (four weeks) were maintained through one year with minimal complications. Our results suggest that MILIF has good-to-excellent outcomes for the treatment of DLD in a broad patient population under different clinical conditions and healthcare delivery systems.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.