Ferrous-sulfate-doped gelatin gel dosimeters are useful tools for the measurement of three-dimensional absorbed radiation dose distributions. The diffusion of ferric ions through these gels causes degradation with time of the dose distribution image. It would be useful to reduce ferric ion diffusion without decreasing gel sensitivity. The amount of ferric ion diffusion is a function of the time delay after radiation, the gel temperature, and the gel concentration. These effects can be quantified by measuring the ferric ion diffusion coefficient. Determination of the diffusion coefficient by irradiating the lower section of a cylinder of gel, which was then imaged repeatedly over time with a clinical magnetic resonance imager, is described. Analysis of the edge spread function formed at each of several times after irradiation by drawing a profile over the imaged junction between the irradiated and unirradiated halves of the cylinder, gave estimates of the variance of the edge spread function. These variances were used to obtain an estimate of the ferric ion diffusion coefficient for the gel. A method of reducing ferric ion diffusion by adding a chelator and the cross linkage agent formaldehyde is suggested. The chelators investigated were 1,10 phenanthroline, xylenol orange, and bathophenanthroline disulfonic acid. These reduced diffusion to varying extents, and influenced the gel sensitivity. The diffusion coefficient in gels containing xylenol orange was found to be 0.44 mm2h-1. The gel sensitivity was 0.0093 s-1Gy-1. This compared with a diffusion coefficient of 0.82 mm2h-1 for the base line gel that did not contain formaldehyde or chelators. The sensitivity of this base line gel was 0.0129 s-1Gy-1. The addition of xylenol orange produced the most improved gel dosimeter of the gels studied. This gel had a decreased ferric ion diffusion coefficient and a decreased sensitivity. It was still sensitive enough to be useful.
AbstractPrimary immunodeficiency (PID) is characterised by recurrent and often life-threatening infections, autoimmunity and cancer, and it presents major diagnostic and therapeutic challenges. Although the most severe forms present in early childhood, the majority of patients present in adulthood, typically with no apparent family history and a variable clinical phenotype of widespread immune dysregulation: about 25% of patients have autoimmune disease, allergy is prevalent, and up to 10% develop lymphoid malignancies1–3. Consequently, in sporadic PID genetic diagnosis is difficult and the role of genetics is not well defined. We addressed these challenges by performing whole genome sequencing (WGS) of a large PID cohort of 1,318 participants. Analysis of coding regions of 886 index cases found disease-causing mutations in known monogenic PID genes in 10.3%, while a Bayesian approach (BeviMed4) identified multiple potential new candidate genes, including IVNS1ABP. Exploration of the non-coding genome revealed deletions in regulatory regions which contribute to disease causation. Finally, a genome-wide association study (GWAS) identified PID-associated loci and uncovered evidence for co-localisation of, and interplay between, novel high penetrance monogenic variants and common variants (at the PTPN2 and SOCS1 loci). This begins to explain the contribution of common variants to variable penetrance and phenotypic complexity in PID. Thus, a cohort-based WGS approach to PID diagnosis can increase diagnostic yield while deepening our understanding of the key pathways influencing human immune responsiveness.
Cryptococcal induced visual loss is a devastating complication in survivors of cryptococcal meningitis (CM). Early detection is paramount in prevention and treatment. Subclinical optic nerve dysfunction in CM has not hitherto been investigated by electrophysiological means. We undertook a prospective study on 90 HIV sero-positive patients with culture confirmed CM. Seventy-four patients underwent visual evoked potential (VEP) testing and 47 patients underwent Humphrey's visual field (HVF) testing. Decreased best corrected visual acuity (BCVA) was detected in 46.5% of patients. VEP was abnormal in 51/74 (68.9%) right eyes and 50/74 (67.6%) left eyes. VEP P100 latency was the main abnormality with mean latency values of 118.9 (±16.5) ms and 119.8 (±15.7) ms for the right and left eyes respectively, mildly prolonged when compared to our laboratory references of 104 (±10) ms (p<0.001). Subclinical VEP abnormality was detected in 56.5% of normal eyes and constituted mostly latency abnormality. VEP amplitude was also significantly reduced in this cohort but minimally so in the visually unimpaired. HVF was abnormal in 36/47 (76.6%) right eyes and 32/45 (71.1%) left eyes. The predominant field defect was peripheral constriction with an enlarged blind spot suggesting the greater impact by raised intracranial pressure over that of optic neuritis. Whether this was due to papilloedema or a compartment syndrome is open to further investigation. Subclinical HVF abnormalities were minimal and therefore a poor screening test for early optic nerve dysfunction. However, early optic nerve dysfunction can be detected by testing of VEP P100 latency, which may precede the onset of visual loss in CM.
Objective
This study explored personal protective equipment (PPE) availability and PPE utilization among interventionalists in the catheterization laboratory, which is a highly contextualized workplace.
Methods
This is a cross-sectional study using mixed methods. Participants (108) completed a survey. A hyperlink was sent to the participants, or they were asked to complete a paper-based survey. Purposively selected participants (54) were selected for individual (30) or group (six) interviews. The interviews were conducted at conferences, or appointments were made to see the participants. Logistic regression analysis was performed. The qualitative data were analyzed thematically.
Results
Lead glasses were consistently used 10.2% and never used 61.1% of the time. All forms of PPE were inconsistently used by 92.6% of participants. Women were 4.3 times more likely to report that PPE was not available. PPE compliance was related to fit and availability.
Conclusions
PPE use was inconsistent and not always available. Improving the culture of radiation protection in catheterization laboratories is essential to improve PPE compliance with the aim of protecting patients and operators. This culture of radiation protection must include all those involved including the users of PPE and the administrators and managers who are responsible for supplying sufficient, appropriate, fitting PPE for all workers requiring such protection.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.