STUDY QUESTION What is the interobserver and intraobserver reproducibility of pelvic ultrasound for the detection of endometriotic lesions? SUMMARY ANSWER Pelvic ultrasound is highly reproducible for the detection of pelvic endometriotic lesions. WHAT IS KNOWN ALREADY Transvaginal ultrasound (TVS) has been widely adopted as the first-line assessment for the diagnosis and assessment of pelvic endometriosis. Severity of endometriosis as assessed by ultrasound has been shown to have good concordance with laparoscopy (kappa 0.79). The reproducibility of TVS for assessment of ovarian mobility and pouch of Douglas obliteration using the ‘sliding sign’ has already been described in the literature. However, there is no available data in the literature to demonstrate the intraobserver repeatability of measurements for endometriotic cysts and nodules. STUDY DESIGN, SIZE, DURATION This was a prospective observational cross-sectional study conducted over a period of 12 months. We included 50 consecutive women who were all examined by two operators (A and B) during their clinic attendance. PARTICIPANTS/MATERIALS, SETTING, METHODS The study was carried out in a specialist endometriosis centre. We included all consecutive women who had ultrasound scans performed independently by two experienced operators during the same visit to the clinic. The outcomes of interest were the inter- and intraobserver reproducibility for the detection of endometriotic lesions. We also assessed repeatability of the measurements of lesion size. MAIN RESULTS AND THE ROLE OF CHANCE There was a good level of agreement between operator A and operator B in detecting the presence of pelvic endometriotic lesions (k = 0.72). There was a very good level of agreement between operators in identifying endometriotic cysts (k = 0.88) and a good level of agreement in identifying endometriotic nodules (k = 0.61). The inter- and intraobserver repeatability of measuring endometriotic cysts was excellent (intra-class correlation (ICC) ≥ 0.98). There was good interobserver measurement repeatability for bowel nodules (ICC 0.88), but the results for nodules in the posterior compartment were poor (ICC 0.41). The intraobserver repeatability for nodule size measurements was good for both operators (ICC ≥0.86). LIMITATIONS, REASONS FOR CAUTION Within this cohort, there was insufficient data to perform a separate analysis for nodule size in the anterior compartment. All examinations were performed within a specialised unit with a high prevalence of deep endometriosis. Our findings may not apply to operators without intensive ultrasound training in the diagnosis of pelvic endometriosis. WIDER IMPLICATIONS OF THE FINDINGS These findings are important because ultrasound has been widely accepted as the first-line investigation for the diagnosis of pelvic endometriosis, which often determines the need for future investigations and treatment. The detection and measurement of bowel nodules is essential for anticipation of surgical risk and planning surgical excision. STUDY FUNDING/COMPETING INTEREST(S) The authors have no conflict of interest. No funding was obtained for this work.
Objectives To assess the overall accuracy of transvaginal ultrasound (TVS) for diagnosis of all types of extrauterine ectopic pregnancy (EUEP) in a large group of women who were managed surgically. We also aimed to assess the positive predictive value (PPV) of TVS for each of the different ultrasound morphological types of EUEP. Methods This was a retrospective observational study of all pregnant women who underwent emergency surgery following ultrasound diagnosis of EUEP at a single early pregnancy unit between January 2009 and December 2017. The preoperative TVS findings were recorded, including the exact location and morphological type (Type I–V; defined using ultrasound criteria) of EUEP. TVS findings were compared with operative and histological findings. The performance of ultrasound in diagnosing EUEP overall and according to morphological type was assessed, using visual confirmation of ectopic pregnancy at surgery as the reference standard. Results A total of 26 401 women presented with early‐pregnancy complications during the study period, including 1241 (4.7%; 95% CI, 4.5–5.0%) women with a conclusive diagnosis of EUEP on TVS or a presumed diagnosis based on severe pain and significant hemoperitoneum. Surgery was performed in 721/1241 (58.1%; 95% CI, 55.3–60.8%) cases, of which 710 (98.5%; 95% CI, 97.6–99.4%) had a conclusive diagnosis of EUEP on preoperative TVS. The remaining 11 women had severe pain and significant hemoperitoneum and were managed surgically on clinical grounds as an emergency, without an ectopic pregnancy having been identified on ultrasound examination. At laparoscopy, the diagnosis of EUEP was confirmed in 706/710 (99.4%; 95% CI, 98.6–99.8%) women with a positive ultrasound diagnosis and in all 11 women with a presumed ultrasound diagnosis of EUEP. The PPV of preoperative ultrasound for the diagnosis of EUEP was 99.4% (95% CI, 98.6–99.8%) with sensitivity of 98.5% (95% CI, 97.3–99.1%). There was no statistically significant difference in the accuracy of preoperative ultrasound diagnosis between the five morphological types (P = 0.76). Conclusions The accuracy of preoperative ultrasound for diagnosis of EUEP is high. The morphological type of EUEP on TVS had no significant effect on the accuracy of preoperative diagnosis. Copyright © 2019 ISUOG. Published by John Wiley & Sons Ltd.
IntroductionWe aimed to investigate the sensitivity and reliability of two-dimensional ultrasonographic endpoints at the metacarpophalageal joints (MCPJs) and their potential to provide an early and objective indication of a therapeutic response to treatment intervention in rheumatoid arthritis (RA).MethodsA randomized, double-blind, parallel-group, two-center, placebo-controlled trial investigated the effect on ultrasonographic measures of synovitis of repeat dose oral prednisone, 15mg or 7.5mg, each compared to placebo, in consecutive two-week studies; there were 18 subjects in a 1:1 ratio and 27 subjects in a 2:1 ratio, respectively. All subjects met the 1987 American College of Rheumatology criteria for the diagnosis of RA, were ≥18 years-old with RA disease duration ≥6 months, and had a Disease Activity Score 28 based on C-reactive protein (DAS28(CRP)) ≥3.2. Subjects underwent high-frequency (gray-scale) and power Doppler ultrasonography at Days 1 (baseline), 2, 8 and 15 in the dorsal transverse and longitudinal planes of all 10 MCPJs to obtain summated scores of quantitative and semi-quantitative measures of synovial thickness as well as vascularity. The primary endpoint was the summated score of power Doppler area measured quantitatively in all 10 MCPJs in the transverse plane at Day 15. Clinical efficacy was assessed at the same time points by DAS28(CRP).ResultsAll randomized subjects completed the trial. The comparison between daily 15 mg prednisone and placebo at Day 15 yielded a statistically significant treatment effect (effect size = 1.17, P = 0.013) in change from baseline in the primary endpoint, but borderline for prednisone 7.5 mg daily versus placebo (effect size = 0.61, P = 0.071). A significant treatment effect for DAS28(CRP) was only observed at Day 15 in the prednisone 15 mg group (effect size = 0.95, P = 0.032). However, significant treatment effects at all time points for a variety of ultrasound (US) endpoints were detected with both prednisone doses; the largest observed effect size = 2.33. Combining US endpoints with DAS28(CRP) improved the registration of significant treatment effects. The parallel scan inter-reader reliability of summated 10 MCPJ scores were good to excellent (ICC values >0.61) for the majority of US measures.ConclusionsUltrasonography of MCPJs is an early, reliable indicator of therapeutic response in RA with potential to reduce patient numbers and length of trials designed to give preliminary indications of efficacy.Trial RegistrationClinicaltrials.gov identifier: NCT00746512
What is the time required for complete physical resolution of tubal ectopic pregnancies diagnosed on ultrasound imaging in women undergoing successful expectant management? DesignA prospective observational cohort study of 177 women who had successful expectant management of tubal ectopic pregnancy, who attended a single Early Pregnancy Unit between January 2014 and Downloaded for Anonymous User (n/a) at University College London Hospitals NHS Foundation 2020. For personal use only. No other uses without permissio December 2018. All participants were monitored until their serum β-hCG dropped to non-pregnant levels and with two-weekly follow-up ultrasound scans until resolution of the pregnancy. Results112/177 (63.8%, 95% CI 56.3-70.9) of tubal ectopic pregnancies were indiscernible on ultrasound 2 weeks after serum β-hCG had returned to non-pregnant levels. In 8/177 (4.5%, 95% CI 2.0-8.7) physical resolution took longer than 78 days. There was a positive correlation between biochemical and physical resolution of tubal ectopic pregnancy (r=0.21, p=0.006). ConclusionsPhysical resolution of tubal ectopic pregnancy is often prolonged and is positively correlated with initial and maximum β-hCG levels. Our results indicate that β-hCG resolution cannot be used as the end-point of expectant management of tubal ectopic pregnancy, which should be considered when counselling women and planning for future pregnancies.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.