Standard radiographic evaluation for radio-ulnar incongruence in the dog may be associated with relatively poor sensitivity and specificity. Invasive surgical procedures and screening programs that rely on radiographic diagnosis of radio-ulnar incongruence should be discouraged until a more reliable method of diagnosis of this type of elbow joint incongruence is available.
A technique for regional delivery of contrast medium to the foot of the horse to increase the diagnostic utility of computed tomography (CT) for the characterization of soft tissue structures within the hoof capsule was developed. An intraarterial catheter was placed under ultrasound guidance into the medial palmar artery at the level of the carpus to facilitate a steady-state infusion of iodinated contrast medium. Two 5 mm collimated contiguous acquisition CT scans were performed in 10 horses without lameness or radiographic evidence of distal sesamoid bone degeneration. CT examination was performed before and during regional arterial infusion of iodinated contrast medium administered at a rate of 2 ml/s. Cross-sectional area and mean pre- and post-contrast attenuation of the deep digital flexor tendon and the collateral ligaments of the distal interphalangeal joint were quantified from CT images. Soft tissue anatomy of the foot was also qualitatively characterized from pre- and postcontrast images. Catheterization was successful and without complication in all horses. The evaluated tendons and ligaments were clearly visible and had a small (8-20 Hounsfield Unit) but significant (P < 0.05, paired t-test) increase in attenuation during the steady-state infusion of contrast medium. This study should enhance the diagnostic potential of CT by providing baseline quantitative data for comparison with horses affected with soft tissue injuries in the distal extremity causing lameness that is alleviated with a palmar digital nerve block.
Existing reports concerning intervertebral disc disease (IVDD) have focused almost exclusively on dogs, although a small number of individual case reports of IVDD of cats has been published. The medical records of six cats with IVDD were reviewed. Radiographic studies confirmed narrowed intervertebral disc spaces, mineralised intervertebral discs, and one or more extradural compressive lesions of the spinal cord in each cat. All disc extrusions were located in the thoracolumbar region. Surgical decompression of the spinal cord was achieved in all cats by means of hemilaminectomy and removal of compressive extradural material confirmed to be degenerative disc material. Good to excellent neurological recovery was noted in five of the six cats included in this report. Based on this review, it appears that IVDD of cats has many similarities to IVDD of dogs, and that healthy cats with acute intervertebral disc extrusion(s) respond favourably to surgical decompression of the spinal cord.
The ability of duplex Doppler ultrasonography to assist with the diagnosis of urinary tract obstruction was investigated in a study of 5 dogs with surgically induced, unilateral ureteral obstruction. The resistive index (RI) of obstructed kidneys was compared to that of controls and to the contralateral unobstructed kidneys. The RI was also evaluated following relief of obstruction. On the basis of an RL measurement 20.70 indicating obstruction, a sensitivity of 73% and a specificity of 77% was determined for the diagnosis of obstruction with Doppler ultrasonography. Although mean RI was elevated in obstructed kidneys compared to controls, it was concluded that a high false-negative rate (27%) limits the clinical usefulness of Doppler ultrasonography for the detection of urinary obstruction in dogs. The RI difference between obstructed and nonobstructed kidneys was also evaluated within individual animals, but the magnitude of difference between kidneys did not significantly improve the detection rate for obstruction.
The purpose of this study was to determine changes in resistive index (RI) and renal size that occur in normal feline kidney autografts in the immediate post-transplant period. Qualitative changes in renal parenchymal echogenicity and pelvic dilation were also noted, although this was not a major focus of the study. Fourteen domestic short-haired cats underwent bilateral nephrectomies followed by an autograft of the right kidney to either the aorta or external iliac artery. Due to post-operative complications, only nine of these cats completed the study. Ultrasonographic determination of the RI and renal size was made before transplantation and on days 1, 4, 7, 10, and 13 following transplantation. No significant changes in renal RI were identified during the study. Renal size increased significantly, peaking at 63% above baseline on day 7, and stayed elevated at 50% above baseline on day 13. There was no evidence of rejection or other abnormalities found on histologic evaluation of the transplanted kidneys. It was concluded that the RI of normal feline renal autografts does not significantly change in the immediate post-operative period. However, significant renal enlargement, likely due to a combination of post-operative edema and hypertrophy, does occur. This study provides baseline information for comparison with feline allografts in the immediate post-transplant period.
Ultrasonographically guided radiofrequency heat ablation of parathyroid masses is a safe and effective alternative to surgery in dogs with primary hyperparathyroidism.
Videofluoroscopic evaluation of both liquid barium and barium soaked kibble was performed in 11 adult, clinically normal dogs of varying breeds. Each examination was digitized and evaluated frame by frame to establish the normal timing sequence of the pharyngeal phase of swallowing. Closure of the epiglottis was considered the onset of swallowing. The time to each of the following events was recorded: (1) Maximum pharyngeal contraction, (2) Opening of the epiglottis, (3) Opening of the cranial esophageal sphincter, and (4) Closure of the cranial esophageal sphincter. These values were found to be consistent both intra and interpatient. Retrospective analysis of 3 videofluoroscopic examinations from dogs that met the subjective criteria defining cricopharyngeal achalasia was then performed. A statistically significant delay in the time to opening and closure of the cranial esophageal sphincter was found employing both liquid barium and barium soaked kibble in the dogs with cricopharyngeal achalasia.
High‐resolution ultrasonography was evaluated as an alternative to 99mTcO‐4 scintigraphy for examining size and appearance of thyroid glands in hyperthyroid cats. Thyroid ultrasound examinations were performed on 6 normal cats and 14 cats with hyperthyroidism. Thyroid lobe volume was estimated from ultrasound images using the equation for a prolate ellipsoid, π/6 (length * height * width). Total thyroid volume was estimated by adding the volume estimations of the left and right lobes. Thyroid lobes of hyperthyroid cats were considered abnormal if estimated volume exceeded the 99% confidence interval for normal thyroid volume determined from the control group. Scintigraphic examinations performed on hyperthyroid cats were evaluated for unilateral versus bilateral disease and for the presence of ectopic activity. Mean thyroid lobe volume and total thyroid volume for normal cats was 85 and 169 mm3, respectively. Mean thyroid lobe volume and total thyroid volume for hyperthyroid cats was 578 and 889 mm3. There was a significant difference in mean estimated total thyroid volume of normal and hyperthyroid cats. Thyroid lobes with greater than normal TcO‐4 uptake on scintigraphy were larger and had variable homogeneity, echogenicity, and margination on ultrasound examination. There also was an 85.7% agreement of scintigraphy and ultrasonography in differentiating normal from abnormal thyroid lobes. A fair correlation between estimated total thyroid volume of hyperthyroid cats and most recent pretherapy serum thyroxine values were also found. This preliminary study indicates that thyroid ultrasound examination may provide information that is useful for diagnosis and treatment of feline hyperthyroidism. Although ultrasound provides accurate evaluation of the thyroid glands, it cannot replace 99mTcO‐4 scintigraphy for screening of metastatic lesions and ectopic glands.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.