Wearable technologies for personalized monitoring require sensors that track biomarkers often present at low levels. Cortisol-a key stress biomarker-is present in sweat at low nanomolar concentrations. Previous wearable sensing systems are limited to analytes in the micromolar-millimolar ranges. To overcome this and other limitations, we developed a flexible field-effect transistor (FET) biosensor array that exploits a previously unreported cortisol aptamer coupled to nanometer-thin-film In 2 O 3 FETs. Cortisol levels were determined via molecular recognition by aptamers where binding was transduced to electrical signals on FETs. The physiological relevance of cortisol as a stress biomarker was demonstrated by tracking salivary cortisol levels in participants in a Trier Social Stress Test and establishing correlations between cortisol in diurnal saliva and sweat samples. These correlations motivated the development and on-body validation of an aptamer-FET array-based smartwatch equipped with a custom, multichannel, self-referencing, and autonomous source measurement unit enabling seamless, real-time cortisol sweat sensing.
Recent advances in functional low‐melting liquid metals (LMs) provide routes to quickly fabricate wearable devices, which can offer excellent mechanical compliance on human skin compared to conventional rigid wafer‐based electronics. Particularly, the Gallium‐based LM mixtures are promising materials for use as stretchable and flexible circuits in wearable healthcare electronics due to their fantastic electrical conductivity, favorable fluidity, super compliance, and benign biocompatibility. Here, the authors develop a kind of directly‐printed Ni‐GaIn functional amalgams, which can efficiently construct wearable healthcare monitors. Unlike EGaIn, Ni‐GaIn amalgam owns a tunable and enhanced adhesion, which makes it easy to directly paint on various substrate for customized circuits. A wireless power transfer coil printed with these amalgams is presented to demonstrate the electrical stability under different tensile states. Finally, the authors design a wearable healthcare monitor for pulse wave measurement via collecting pulse wave signals from the wrist steadily. With the advantages of stretchability and rapid manufacture, the functional Ni‐GaIn amalgams as currently presented shows a promising approach for individualized wearable electronics.
Active biofluid management is central to the realization of wearable bioanalytical platforms that are poised to autonomously provide frequent, real-time, and accurate measures of biomarkers in epidermally-retrievable biofluids (e.g., sweat). Accordingly, here, a programmable epidermal microfluidic valving system is devised, which is capable of biofluid sampling, routing, and compartmentalization for biomarker analysis. At its core, the system is a network of individually-addressable microheater-controlled thermo-responsive hydrogel valves, augmented with a pressure regulation mechanism to accommodate pressure built-up, when interfacing sweat glands. The active biofluid control achieved by this system is harnessed to create unprecedented wearable bioanalytical capabilities at both the sensor level (decoupling the confounding influence of flow rate variability on sensor response) and the system level (facilitating context-based sensor selection/protection). Through integration with a wireless flexible printed circuit board and seamless bilateral communication with consumer electronics (e.g., smartwatch), contextually-relevant (scheduled/on-demand) on-body biomarker data acquisition/display was achieved.
Recent advances in microelectronics, microfluidics, and electrochemical sensing platforms have enabled the development of an emerging class of fully integrated personal health monitoring devices that exploit sweat to noninvasively access biomarker information. Despite such advances, effective sweat sampling remains a significant challenge for reliable biomarker analysis, with many existing methods requiring active stimulation (e.g., iontophoresis, exercise, heat). Natural perspiration offers a suitable alternative as sweat can be collected with minimal effort on the part of the user. To leverage this phenomenon, we devised a thin hydrogel micropatch (THMP), which simultaneously serves as an interface for sweat sampling and a medium for electrochemical sensing. To characterize the performance of the THMP, caffeine and lactate were selected as two representative target molecules. We demonstrated the suitability of the sampling method to track metabolic patterns, as well as to render sample-to-answer biomarker data for personal monitoring (through coupling with an electrochemical sensing system). To inform its potential application, this biomarker sampling and sensing system is incorporated within a distributed terminal-based sensing network, which uniquely capitalizes on the fingertip as a site for simultaneous biomarker data sampling and user identification.
To achieve the mission of personalized medicine, centering on delivering the right drug to the right patient at the right dose, therapeutic drug monitoring solutions are necessary. In that regard, wearable biosensing technologies, capable of tracking drug pharmacokinetics in noninvasively retrievable biofluids (e.g., sweat), play a critical role, because they can be deployed at a large scale to monitor the individuals’ drug transcourse profiles (semi)continuously and longitudinally. To this end, voltammetry-based sensing modalities are suitable, as in principle they can detect and quantify electroactive drugs on the basis of the target’s redox signature. However, the target’s redox signature in complex biofluid matrices can be confounded by the immediate biofouling effects and distorted/buried by the interfering voltammetric responses of endogenous electroactive species. Here, we devise a wearable voltammetric sensor development strategy—centering on engineering the molecule–surface interactions—to simultaneously mitigate biofouling and create an “undistorted potential window” within which the target drug’s voltammetric response is dominant and interference is eliminated. To inform its clinical utility, our strategy was adopted to track the temporal profile of circulating acetaminophen (a widely used analgesic and antipyretic) in saliva and sweat, using a surface-modified boron-doped diamond sensing interface (cross-validated with laboratory-based assays, R2 ∼ 0.94). Through integration of the engineered sensing interface within a custom-developed smartwatch, and augmentation with a dedicated analytical framework (for redox peak extraction), we realized a wearable solution to seamlessly render drug readouts with minute-level temporal resolution. Leveraging this solution, we demonstrated the pharmacokinetic correlation and significance of sweat readings.
Automated technologies that can perform massively parallelized and sequential fluidic operations at small length scales can resolve major bottlenecks encountered in various fields, including medical diagnostics, -omics, drug development, and chemical/material synthesis. Inspired by the transformational impact of automated guided vehicle systems on manufacturing, warehousing, and distribution industries, we devised a ferrobotic system that uses a network of individually addressable robots, each performing designated micro-/nanofluid manipulation-based tasks in cooperation with other robots toward a shared objective. The underlying robotic mechanism facilitating fluidic operations was realized by addressable electromagnetic actuation of miniature mobile magnets that exert localized magnetic body forces on aqueous droplets filled with biocompatible magnetic nanoparticles. The contactless and high-strength nature of the actuation mechanism inherently renders it rapid (~10 centimeters/second), repeatable (>10,000 cycles), and robust (>24 hours). The robustness and individual addressability of ferrobots provide a foundation for the deployment of a network of ferrobots to carry out cross-collaborative logistics efficiently. These traits, together with the reconfigurability of the system, were exploited to devise and integrate passive/active advanced functional components (e.g., droplet dispensing, generation, filtering, and merging), enabling versatile system-level functionalities. By applying this ferrobotic system within the framework of a microfluidic architecture, the ferrobots were tasked to work cross-collaboratively toward the quantification of active matrix metallopeptidases (a biomarker for cancer malignancy and inflammation) in human plasma, where various functionalities converged to achieve a fully automated assay.
Acoustic tweezers based on circular, slanted-finger interdigital transducers enable programmable, dynamic, biocompatible manipulation of micro-objects.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.