The optimal catheter ablation (CA) strategy for patients with persistent atrial fibrillation (PeAF) and heart failure (HF) remains uncertain. Between 2016 and 2020, 118 consecutive patients with PeAF and HF who underwent the CA procedure in two centers were retrospectively evaluated and divided into the pulmonary vein isolation (PVI)-only and PVI + additional ablation groups. Transthoracic echocardiography (TTE) was performed at baseline, one month, and 12 months after the CA procedure. The HF symptoms and left ventricular ejection fraction (LVEF) improvements were analyzed. Fifty-six patients underwent PVI only, and 62 patients received PVI with additional ablation. Compared with the baseline, a significant improvement in the LVEF and left atrial diameter postablation was observed in all patients. No significant HF improvement was detected in the PVI + additional ablation group than in the PVI-only group (74.2% vs. 71.4%, P = 0.736 ), but the procedure and ablation time were significantly longer (137.4 ± 7.5 vs. 123.1 ± 11.5 min, P = 0.001 ). There was no significant difference in the change in TTE parameters and the number of rehospitalizations. For patients with PeAF and HF, CA appears to improve left ventricular function. Additional ablation does not improve outcomes and has a significantly longer procedure time. Trial registration number is as follows: ChiCTR2100053745 (Chinese Clinical Trial Registry; https://www.chictr.org.cn/index.aspx).
A 70-year-old man with severe valvular cardiomyopathy, permanent atrial fibrillation (AF) with a slow ventricular response, and transient atrioventricular (AV) block, was admitted to our center for severe heart failure and recurrent presyncope. While hospitalized, the coronary computed tomography angiography (CTA) showed huge atriums. We tried His bundle pacing (HBP). HB potential was observed at site A, and the His-ventricular (HV) interval was 68 ms. The duration from the stimulus signal to the onset of paced QRS (S-QRSonset) at site A was 232 ms when pacing at 60 beats per minute (BPM) with the pacing threshold of 2.0 V/0.5 ms. The S-QRSonset was longer than the HV interval and had a notable and progressive prolongation from 252 ms to 456 ms during the pacing at 90 BPM. Then, we pushed another lead a little forward, and the S-QRSonset shortened back to 68 ms, and the paced QRS morphology was the same as the intrinsic QRS morphology with the pacing threshold of 1.5 V/0.5 ms. The progressively prolonged S-QRSonset demonstrated a Wenckebach phenomenon (WP), a well-known electrophysiological characteristic of the AV node (AVN). It is the first time to report an intraoperative AVN-pacing related-WP in a patient with persistent AF. The enlarged atrium might be convenient for capturing the AVN. There are some other potential explanations for this phenomenon. The diameters of atriums decreased significantly, and the symptoms improved after the procedure. This is the first reported case in which we might achieve AVN capture in a patient with persistent AF. Although we ultimately chose HBP for better long-term pacing thresholds, the result of this case suggested that AVN pacing may be possible.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.