We present a parameter estimation technique based on performing joint measurements of a weak interaction away from the weak-value-amplification approximation. Two detectors are used to collect full statistics of the correlations between two weakly entangled degrees of freedom. Without discarding of data, the protocol resembles the anomalous amplification of an imaginary-weak-value-like response. The amplification is induced in the difference signal of both detectors allowing robustness to different sources of technical noise, and offering in addition the advantages of balanced signals for precision metrology. All of the Fisher information about the parameter of interest is collected. A tunable phase controls the strength of the amplification response. We experimentally demonstrate the proposed technique by measuring polarization rotations in a linearly polarized laser pulse. We show that in the presence of technical noise the effective sensitivity and precision of a split detector is increased when compared to a conventional continuous-wave balanced detection technique.Introduction Anomalous amplification [1] has been shown to be advantageous for precision metrology. Such an amplification provides a way to increase a signal while decreasing [2] or retaining the technical-noise floor [3,4]. As a result, the sensitivity and precision of measurements limited by technical noise can be effectively improved, facilitating the saturation of the standard quantum limit. Anomalous amplification was first proposed for metrology with the introduction of the Weak Value (WV) of an observable [1,5], and parameter estimation protocols defined after it are usually known as Weak-ValueAmplification (WVA) techniques. The WV of an observable is obtained by post-selecting the state of a system after a weak interaction with a meter system. In WVA, such measurements in the system induce a discarding of data counts in the measurements of the meter. In addition to the notion that the state of the system is post-selected after the weak interaction, we consider post-selection as the process of selecting and processing desired events, which, for WVA, results in discarding data in the meter. Due to the interference of the pre-and post-selection states of the system the WV can take large complex values outside the eigenvalue spectrum of the observable, which defines the anomalous amplification in WVA. Discussion about the quantum interpretation of such a phenomenon can be found in Refs. [6][7][8][9]. Many recent applications of WVA for metrology have been done in classical optics, where the interference can be understood using standard wave mechanics [10,11].
The technique of almost-balanced weak values amplification (ABWV) was recently proposed [Phys. Rev. Lett. 116: 100803 (2016)]. We demonstrate this technique using a modified Sagnac interferometer, where the counter-propagating beams are spatially separated. The separation between the two beams provides additional amplification, with respect to using colinear beams in a Sagnac interferometer. As a demonstration of the technique, we perform measurements of the angular velocity in one of the mirrors of the interferometer. Within the same setup, the weak-value amplification technique is also performed for comparison. Much higher amplification factors can be obtained using the almost-balanced weak values technique, with the best one achieved in our experiments being as high as 1.2 × 10 7 . In addition, the amplification factor monotonically increases with decreasing post-selection phase for the ABWV case in our experiments, which is not the case for weak-value amplification at small post-selection phases.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.