Synthetic biology is an emerging field focused on engineering biomolecular systems and cellular capabilities for a variety of applications. Substantial progress began a little over a decade ago with the creation of synthetic gene networks inspired by electrical engineering. Since then, the field has designed and built increasingly complex circuits and constructs and begun to use these systems in a variety of settings, including the clinic. These efforts include the development of synthetic biology therapies for the treatment of infectious diseases and cancer, as well as approaches in vaccine development, microbiome engineering, cell therapy, and regenerative medicine. Here, we highlight advances in the biomedical application of synthetic biology and discuss the field's clinical potential.
Sea ice typically forms at the ocean's surface, but given a source of supercooled water, an unusual form of ice--anchor ice--can grow on objects in the water column or at the seafloor. For several decades, ecologists have considered anchor ice to be an important agent of disturbance in the shallow-water benthic communities of McMurdo Sound, Antarctica, and potentially elsewhere in polar seas. Divers have documented anchor ice in the McMurdo communities, and its presence coincides with reduced abundance of the sponge Homaxinella balfourensis, which provides habitat for a diverse assemblage of benthic organisms. However, the mechanism of this disturbance has not been explored. Here we show interspecific differences in anchor-ice formation and propagation characteristics for Antarctic benthic organisms. The sponges H. balfourensis and Suberites caminatus show increased incidence of formation and accelerated spread of ice crystals compared to urchins and sea stars. Anchor ice also forms readily on sediments, from which it can grow and adhere to organisms. Our results are consistent with, and provide a potential first step toward, an explanation for disturbance patterns observed in shallow polar benthic communities. Interspecific differences in ice formation raise questions about how surface tissue characteristics such as surface area, rugosity, and mucus coating affect ice formation on invertebrates.
Microfluidics are widely used in research ranging from bioengineering and biomedical disciplines to chemistry and nanotechnology. As such, there are a large number of options for the devices used to drive and control flow through microfluidic channels. Commercially available syringe pumps are probably the most commonly used instruments for this purpose, but are relatively high-cost and have inherent limitations due to their flow profiles when they are run open-loop. Here, we present a low-cost ($110) syringe pressure pump that uses feedback control to regulate the pressure into microfluidic chips. Using an open-source microcontroller board (Arduino), we demonstrate an easily operated and programmable syringe pump that can be run using either a PID or bang-bang control method. Through feedback control of the pressure at the inlets of two microfluidic geometries, we have shown stability of our device to within ±1% of the set point using a PID control method and within ±5% of the set point using a bang-bang control method with response times of less than 1 second. This device offers a low-cost option to drive and control well-regulated pressure-driven flow through microfluidic chips.
Observations of material and cellular systems in response to time-varying chemical stimuli can aid the analysis of dynamic processes. We describe a microfluidic “chemical signal generator,” a technique to apply continuously varying chemical concentration waveforms to arbitrary locations in a microfluidic channel through feedback control of the interface between parallel laminar (co-flowing) streams. As the flow rates of the streams are adjusted, the channel walls are exposed to a chemical environment that shifts between the individual streams. This approach can be used to probe the dynamic behavior of objects or substances adherent to the interior of the channel. To demonstrate the technique, we exposed live fibroblast cells to ionomycin, a membrane-permeable calcium ionophore, while assaying cytosolic calcium concentration. Through the manipulation of the laminar flow interface, we exposed the cells' endogenous calcium handling machinery to spatially-contained discrete and oscillatory intracellular disturbances, which were observed to elicit a regulatory response. The spatiotemporal precision of the generated signals opens avenues to previously unapproachable areas for potential investigation of cell signaling and material behavior.
Termination of cyclic adenosine monophosphate (cAMP) signaling via the extracellular Ca2+-sensing receptor (CaR) was visualized in single CaR-expressing human embryonic kidney (HEK) 293 cells using ratiometric fluorescence resonance energy transfer–dependent cAMP sensors based on protein kinase A and Epac. Stimulation of CaR rapidly reversed or prevented agonist-stimulated elevation of cAMP through a dual mechanism involving pertussis toxin–sensitive Gαi and the CaR-stimulated increase in intracellular [Ca2+]. In parallel measurements with fura-2, CaR activation elicited robust Ca2+ oscillations that increased in frequency in the presence of cAMP, eventually fusing into a sustained plateau. Considering the Ca2+ sensitivity of cAMP accumulation in these cells, lack of oscillations in [cAMP] during the initial phases of CaR stimulation was puzzling. Additional experiments showed that low-frequency, long-duration Ca2+ oscillations generated a dynamic staircase pattern in [cAMP], whereas higher frequency spiking had no effect. Our data suggest that the cAMP machinery in HEK cells acts as a low-pass filter disregarding the relatively rapid Ca2+ spiking stimulated by Ca2+-mobilizing agonists under physiological conditions.
Microfluidic technologies are frequently employed as point-of-care diagnostic tools for improving time-to-diagnosis and improving patient outcomes in clinical settings. These microfluidic devices often are designed to operate with peripheral equipment for liquid handling that increases the cost and complexity of these systems and reduces their potential for widespread adoption in low resource healthcare applications. Here, we present a low-cost (~$120), open-source peristaltic pump constructed with a combination of three dimensional (3D)-printed parts and common hardware, which is amenable to deployment with microfluidic devices for point-of-care diagnostics. This pump accepts commonly available silicone rubber tubing in a range of sizes from 1.5 to 3 mm, and is capable of producing flow rates up to 1.6 mL min −1 . This device is programmed with an Arduino microcontroller, allowing for custom flow profiles to fit a wide range of low volume liquid handling applications including precision liquid aliquoting, flow control within microfluidics, and generation of physiologically relevant forces for studying cellular mechanobiology within microfluidic systems.Microfluidic systems are ubiquitous tools within science and engineering laboratories around the world that enable low-cost and high throughput analysis via the miniaturization and parallelization of experimental systems. To enable broader applications and lower the barrier to entry for using microfluidic technology, developing open-source and low-cost tools for handling fluids is a promising avenue of research 1-3 . Open-source microfluidic tools could be particularly impactful when used for point-of-care diagnostics in resource limited settings. The growing use of microfluidics in point-of-care diagnostic roles is driven by the desire for more personalized medical treatments that are tailored to the specific pathologies identified in the patient 4-7 . This is because assays that can be performed at the point of care dramatically improve time-to-diagnosis, leading to improvements in medical practitioner decision making and patient outcomes 8 . In order for point-of-care diagnostic devices to be widely adopted into more clinical settings so that they can effectively improve healthcare outcomes, advances must be made in key enabling technologies, including improved microfluidic device designs, and improved peripheral systems for fluid actuation and sensing 9 . Increasing the use of open-source tools for future point-of-care diagnostic tools would enable reductions in system cost, and increase ease of use.Microfluidic point-of-care diagnostic systems must include three basic components: the physical microfluidic device, systems to read the assay output, and systems to control the flow of liquid reagents (Fig. 1A). The physical microfluidic device can be manufactured from a wide range of low-cost materials, including PDMS 10
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.