The abuse of unknown designer androgenic anabolic steroids (AAS) is considered to be an issue of significant importance, as AAS are the choice of doping preference according to World Anti-doping Agency statistics. In addition, unknown designer AAS are preferred since the World Anti-doping Agency mass spectrometric identification criteria cannot be applied to unknown molecules. Consequently, cheating athletes have a strong motive to use designer AAS in order to both achieve performance enhancement and to escape from testing positive in anti-doping tests. To face the problem, a synergy is required between the anti-doping analytical science and sports anti-doping regulations. This Review examines various aspects of the designer AAS. First, the structural modifications of the already known AAS to create new designer molecules are explained. A list of the designer synthetic and endogenous AAS is then presented. Second, we discuss progress in the detection of designer AAS using: mass spectrometry and bioassays; analytical data processing of the unknown designer AAS; metabolite synthesis; and, long-term storage of urine and blood samples. Finally, the introduction of regulations from sports authorities as preventive measures for long-term storage and reprocessing of samples, initially reported as negatives, is discussed.
This paper presents the development and validation of a high-resolution full scan (FS) electron impact ionization (EI) gas chromatography coupled to quadrupole Time-of-Flight mass spectrometry (GC/QTOF) platform for screening anabolic androgenic steroids (AAS) in human urine samples. The World Antidoping Agency (WADA) enlists AAS as prohibited doping agents in sports, and our method has been developed to comply with the qualitative specifications of WADA to be applied for the detection of sports antidoping prohibited substances, mainly for AAS. The method also comprises of the quantitative analysis of the WADA's Athlete Biological Passport (ABP) endogenous steroidal parameters. The applied preparation of urine samples includes enzymatic hydrolysis for the cleavage of the Phase II glucuronide conjugates, generic liquid-liquid extraction and trimethylsilyl (TMS) derivatization steps. Tandem mass spectrometry (MS/MS) acquisition was applied on few selected ions to enhance the specificity and sensitivity of GC/TOF signal of few compounds. The full scan high resolution acquisition of analytical signal, for known and unknown TMS derivatives of AAS provides the antidoping system with a new analytical tool for the detection designer drugs and novel metabolites, which prolongs the AAS detection, after electronic data files' reprocessing. The current method is complementary to the respective liquid chromatography coupled to mass spectrometry (LC/MS) methodology widely used to detect prohibited molecules in sport, which cannot be efficiently ionized with atmospheric pressure ionization interface.
The population based Steroid Profile (SP) ratio of testosterone (T) and epitestosterone (E) has been considered as a biomarker approach to detect testosterone abuse in '80s. The contemporary Antidoping Laboratories apply the World Antidoping Agency (WADA) Technical Document (TD) for Endogenous Androgenic Anabolic Steroids (EAAS) in the analysis of SP during their screening. The SP Athlete Biological Passport (ABP) adaptive model uses the concentrations of the total of free and glucuronide conjugated forms of six EAASs concentrations and ratios measured by GC/MS. In the Antidoping Lab Qatar (ADLQ), the routine LC/MS screening method was used to quantitatively estimate the sulfate conjugated EAAS in the same analytical run as for the rest qualitative analytes. Seven sulfate EAAS were quantified for a number of routine antidoping male and female urine samples during screening. Concentrations, statistical parameters and selected ratios for the 6 EAAS, the 6 sulfate EAAS and 29 proposed ratios of concentrations from both EAAS and sulfate EAAS, which potentially used as SP ABP biomarkers, population reference limits and distributions have been estimated after the GC/MSMS analysis for EAAS and LC/Orbitrap/MS analysis for sulfate EAAS.
The data presented herein proved that both molecular profiling platforms can be used for antidoping screening. The mass accuracies are excellent in both instruments; however, the GC/Q-Orbitrap performs better as it provides higher resolution than the GC/Q-TOF platform.
The World Antidoping Agency (WADA) Monitoring program concentrates analytical data from the WADA Accredited Laboratories for substances which are not prohibited but whose potential misuse must be known. The WADA List of Monitoring substances is updated annually, where substances may be removed, introduced or transferred to the Prohibited List, depending on the prevalence of their use. Retroactive processing of old sample datafiles has the potential to create information for the prevalence of use of candidate substances for the Monitoring List in previous years. MetAlign is a freeware software with functionality to reduce the size of liquid chromatography (LC)/ high-resolution (HR) full-scan (FS) mass spectrometry (MS) datafiles and to perform a fast search for the presence of substances in thousands of reduced datafiles. Methods: Validation was performed to the search procedure of MetAlign applied to Anti-Doping Lab Qatar (ADLQ)-screened LC/HR-FS-MS reduced datafiles originated from antidoping samples for tramadol (TRA), ecdysterone (ECDY) and the ECDY metabolite 14-desoxyecdysterone (DESECDY) of the WADA Monitoring List. Searching parameters were related to combinations of accurate masses and retention times (RTs). Results: MetAlign search validation criteria were based on the creation of correct identifications, false positives (FPs) and false negatives (FNs). The search for TRA in 7410 ADLQ routine LC/HR-FS-MS datafiles from the years 2017 to 2020 revealed no false identification (FPs and FNs) compared with the ADLQ WADA reports. ECDY Safa Khelifi and Khadija Saad contributed equally to this work.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.