Comparisons forgamma rays between the exposure standards of the Bureau International des Poids et Mesures (BIPM), the National Bureau of Standards (NBS) and the Physikalisch-Technische Bundesanstalt (PTB) are reported. For measuremente made at about one meter from the source, and if the same physical constants are used, the differences are 0.26% between the BIPM and NBS standards, and a t most 0.4% between the BIPM standard and the PTB standard chambers. The differences are consistent with the estimated systematic uncertainties (= 0.5 %).The difference between the NBS standard and the PTB chamber measurements, as determined through the ratios of each to the BIPM chamber, ranges from 0.17 to 0.66%. The difference in exposure standards for NBS and PTB actually ranges from 0.48 to 0.97%, since different stopping power corrections are used by these two laboratories.An indirect comparison of the BIPM and NBS standards indicates that the difference of 0.26% will increase to 0.55% a t a distance of two meters. RBsumBOn relate des comparaisons entre Btalons de mesure de l'exposition dans un faisceau de rayons gamma du 6OCo: ceux du Bureau International des Poids et Mesures (BIPM), du National Bureau of Standards (NBS) et de la Physikalisch-Technische Bundesanstalt (PTB). Pour les mesures effectuBes B un metre environ de la source et si Yon utilise les m6mes constantes physiques, les Bcarta sont 0,26y0 entre les &talons du BIPM et du NBS, et au plus 0,4 % entre 1'Btalon du BIPM et les chambres Btalons de la PTB. Ces diffhrences sont compatibles avec les incertitudes systBmatiques estimbes (= 0,5 %).Les diffbrences entre les mesures de 1'6talon du NBS et des chambres de la PTB, telles qu'on peut les dBduire de leurs rapports respectifs la chambre du BIPM, sont comprises entre 0,17 et 0,66%. Les d8Brences entre lea Btalons #exposition du NBS et de la PTB sont en rBalit6 comprises entre 0,48 et 0,97 % puisque ces deux laboratoires utilisent des corrections de pouvoir de ralentissement d8Brentes.Une comparaison indirecte des Btalons du BIPM et du NBS montre que la diffkrence 0,26% deviendrait 0,55% B unc distance de deux mhtres.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.