In the first part with on-line HDF, starting from HDF 60 ml/min a significantly higher beta2-M reduction ratio and clearance vs HD is noted. In HDF100 (i.e. with 241 replacement volume per 4-h treatment) vs HD, a beta2-M reduction ratio of 72.7% vs 49.7% (P= 0.0000) and a beta2-M clearance of 116.8 vs 63.8 ml/min (P=0.0000) was obtained. Comparing HDF120 with HDF100, there is a significantly higher beta2-M clearance with the former (P<0.005), although the beta2-M reduction ratio was not significantly better. In the HDF120 session the amount of beta2-M in the total dialysate was 292 mg per session. If one adds the known 17% adsorption on the polysulfone membrane, a total of 341.6 mg beta2-M per session is removed, which adds up to 1024.8 mg a week. Concerning the small molecules, our results with HDF100 also show a higher creatinine and especially P clearance vs HD. In the second part with 16 patients with more than 10 years of dialysis treatment (mean 14 years 1 month), the mean time on HDF amounted to 39.5% of the total treatment time. In four patients only biocompatible and highly permeable membranes were used, AN69 and mainly polysulfone, and in four other patients these membranes were used for more than 95% of the treatment time. Therefore, it is not surprising that the prevalence of carpal tunnel syndrome was only 12.5% in the patients after 10 years of dialysis. Twenty-five percent of these patients met the criteria for diagnosis of beta2-M bone-amyloidosis, proposed by van Ypersele de Strihou et al., but without a retrospective X-ray analysis. The mean predialysis beta2-M value was 29.6 mg/l. The mean values for serum albumin, serum total cholesterol, HDL and LDL cholesterol were within normal limits. For the parathyroid hormone a mean of 287.5 pg/ml was found. Subtotal parathyroidectomy was performed in five patients. The mean dose of 43 U erythropoietin/kg per session is comparable with those reported in the literature. Conclusions. Like Canaud, in our renal unit, treatment with on-line HDF with a highly permeable and biocompatible membrane has proven to be an efficient, well-tolerated and safe technique. Furthermore it leads to a low prevalence of dialysis amyloidosis and a superior P clearance. However, continuous attention must be paid to an on-line sterile and apyrogenic dialysate. Although on-line HDF is undoubtedly a more optimal approach of chronic dialytic treatment, it also carries a higher cost, which is currently evaluated to be nearly US$11 per session.
Eight chronic, anuric hemodialysis patients were randomly treated with a high-flux polysulphone dialyzer (F80), using 6 different modes: conventional bicarbonate hemodialysis (HD), hemodiafiltration (HDF) with a replacement solution at 40, 60, 80 or 100 ml/min in postdilution and 80 ml/min in predilution. The differences in β2-microglobulin (β2M) reduction ratio and clearance were evaluated statistically by analysis of variance (ANOVA). Both studies revealed no significant difference between HD and HDF40 in postdilution, but an increasing significant difference from HDF60 to HDF100 in postdilution and with HDF80 in predilution. The mean reduction ratio ranged from 49.7 (HD) to 72.7% (HDF 100 ml/min), showing an overall statistically significant difference (p = 0.0000). For the clearance, the range was between 63.8 (HD) and 116.8 ml/min (HDF 100 ml/min) (p = 0.0000). β2M in the effluent dialysate with HDF100 ml/min reached up to a mean of 258 mg/session. Concerning small molecules (BUN, creatinine and P), there was a statistically significant different clearance for creatinine and especially for P with HDF 100 ml/min. Conclusion: HDF with an on-line replacement solution at 100 ml/min and a high-flux and biocompatible polysulphone membrane represents a new tool for enhanced removal of β2M. Besides a significant increase in creatinine and especially in phosphorus clearance is noted.
Guanidino compounds are increased in uremia and are highly suspected to be uremic toxins. The serum levels of 11 guanidino compounds and the influence of a single hemodialysis were evaluated in 30 steady-state uremic patients undergoing maintenance hemodialysis. Guanidino compound levels were detected using liquid cation exchange chromatography with a highly sensitive fluorescence detection method. Highly standardized dialysis procedures were performed. Before hemodialysis, high levels were found for guanidinosuccinic acid, N-α-acetylarginine, argininic acid, creatinine, γ-guanidinobutyric acid, guanidine and methylguanidine. Guanidinosuccinic acid reached levels associated with toxic effects in vitro. After hemodialysis, although lowered, guanidinosuccinic acid, creatinine, guanidine and methylguanidine were still markedly increased. No differences in the percent decrease, during a single hemodialysis, of the studied compounds were found using different membranes such as cellulose acetate, cuprophane and polyacrylonitrile membranes. Substantial differences, however, in the percent decrease of the different guanidino compounds were found, ranging from 25 ± 13% for arginine to 74 ± 7.5% for guanidinosuccinic acid. Data reported here show that guanidino compounds are raised in serum of uremic patients undergoing maintenance hemodialysis, before as well as after a single hemodialysis, while substantial differences in the percent decrease of the different guanidino compounds are found.
Recently, well performing diagnostic criteria for analgesic nephropathy in end-stage renal failure (ESRF) patients were defined by the demonstration of a bilateral decrease in renal volume combined with either bumpy contours or papillary calcifications. In this study, the diagnostic value of computed tomography (CT) scan was compared to the previously used renal imaging techniques (sonography and conventional tomography). In a first study, a cohort of 40 analgesic abusers (defined as daily use of analgesic mixtures during at least 5 years) and 40 controls, all ESRF patients without a clear renal diagnosis, were investigated with sonography, tomography and CT scan without injection of iodinated contrast material, to search for the imaging signs of analgesic nephropathy. Using CT scan, sonography and tomography, renal size could be evaluated with comparable results while CT scan was superior in the detection of papillary calcifications (sensitivity 87%, specificity 97%). In a second controlled study of 53 analgesic abusers with a serum creatinine between 1.5 to 4 mg/dl in the absence of a clear renal diagnosis, a CT scan was performed and scored for the presence of decreased renal volume, bumpy contours and papillary calcifications. It was found that the renal image of analgesic nephropathy on CT scan in an early stage of renal failure is comparable with the observations made in ESRF patients. Particularly the demonstration of papillary calcifications showed a high sensitivity of 92% with a specificity of 100% for the early diagnosis of analgesic nephropathy.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.