Continuous hemofiltration increases IL-6 plasma clearance but not TNF alpha clearance. However, hemofiltration failed to decrease plasma concentrations of TNF alpha and IL-6 and, therefore, cannot be used effectively for cytokine elimination in SIRS. Accordingly, beneficial effects occasionally reported with hemofiltration are unlikely to be expected due to elimination of IL-6 or TNF alpha.
During inhalation induction with 8% sevoflurane in 60% nitrous oxide, rocuronium 0.29 mg kg-1 (ED95) optimizes intubation conditions for surgery of short duration.
Conflicting reports on the usefulness of intraoperative monitoring of visual function by means of visual evoked potentials (VEPs) initiated this study. In 32 patients without visual problems, VEPs were recorded to evaluate the reliability for intraoperative monitoring with total intravenous anesthesia. All patients underwent noncranial surgery. Using a standard technique, VEPs were recorded preoperatively in the awake patients and after induction of anesthesia during surgery. A total of 1436 intraoperative traces were recorded and analyzed. A minor prolongation of the P100 latency of 8% and a more pronounced attenuation of the P100-N145 amplitude of 60% were observed in the anesthetized patients. In most of the anesthetized patients, a stable recording of VEPs was not obtainable. In 4 patients (12.5%), clearly identifiable VEP peaks were detected in more than 90% of the traces recorded intraoperatively. In 88% of the patients, reproducible VEPs were obtained in less than 75% of the intraoperative traces only. We concluded that with standard recording techniques and total intravenous anesthesia, intraoperative VEP monitoring in surgically anesthetized patients is not reliable.
BackgroundInterscalene brachial plexus (ISB) block is often associated with phrenic nerve block and diaphragmatic paresis. The goal of our study was to test if the anterior or the posterior ultrasound guided approach of the ISB is associated with a lower incidence of phrenic nerve blocks and impaired lung function.MethodsThis was a prospective, randomized and single-blinded study of 84 patients scheduled for elective shoulder surgery who fullfilled the inclusion and exclusion critereria. Patients were randomized in two groups to receive either the anterior (n = 42) or the posterior (n = 42) approach for ISB. Clinical data were recorded. In both groups patients received ISB with a total injection volume of 15 ml of ropivacaine 1 %. Spirometry was conducted at baseline (T0) and 30 min (T30) after accomplishing the block.Changes in spirometrical variables between T0 and T30 were investigated by Wilcoxon signed-rank test for each puncture approach. The temporal difference between the posterior and the anterior puncture approach groups were again analyzed by the Wilcoxon-Mann-Whitney test.ResultsThe spirometric results showed a significant decrease in vital capacity, forced expiratory volume per second, and maximum nasal inspiratory breathing after the Interscalene brachial plexus block; indicating a phrenic nerve block (p <0.001, Wilcoxon signed-rank). A significant difference in the development of the spirometric parameters between the anterior and the posterior group could not be identified (Wilcoxon-Mann-Whitney test). Despite the changes in spirometry, no cases of dyspnea were reported.ConclusionA different site of injection (anterior or posterior) did not show an effect in reducing the cervical block spread of the local anesthetic and the incidence of phrenic nerve blocks during during ultrasound guided Interscalene brachial plexus block. Clinical breathing effects of phrenic nerve blocks are, however, usually well compensated, and subjective dyspnea did not occur in our patients.Trial registrationGerman Clinical Trials Register (DRKS number 00009908, registered 26 January 2016).
We conclude from this study, that steady-state visual evoked potential recordings in the surgically anaesthetized patient appeared to be more stable compared to our earlier findings using transient visual evoked potentials. However, further efforts are necessary to improve the stability of the recordings during surgery and thus allow for a more reliable intraoperative monitoring of visual pathways in routine clinical practice.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.