There are many various methods, techniques and materials for constructing multifunctional inverted flat roofs now. However, in practice, the constructed roofs of this type often have various defects, whose elimination is rather costly. To solve this problem, the analysis of multifunctional inverted flat roofs has been performed and their advantages and disadvantages, as well as building defects and mistakes made in the course of construction, have been demonstrated. Damp-proofing materials available on the market for making waterproofing membranes for multifunctional inverted flat roofs have been evaluated. The problem of choosing the most effective membrane alternative for the investigated type of roofs is solved by analysing ten alternatives with the help of multi-criteria evaluation method, SAW and three game theory rules determined by Hurwicz, Laplace and Bayes, as well as LEVI 3.0 program. The analysis of the results has shown that the alternative No. 5 is the best membrane alternative among the ten considered options.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.