Background Although a growing number of studies focus on the measurement and detection of freezing of gait (FoG) in laboratory settings, only a few studies have attempted to measure FoG during daily life with body-worn sensors. Here, we presented a novel algorithm to detect FoG in a group of people with Parkinson’s disease (PD) in the laboratory (Study I) and extended the algorithm in a second cohort of people with PD at home during daily life (Study II). Methods In Study I, we described of our novel FoG detection algorithm based on five inertial sensors attached to the feet, shins and lumbar region while walking in 40 participants with PD. We compared the performance of the algorithm with two expert clinical raters who scored the number of FoG episodes from video recordings of walking and turning based on duration of the episodes: very short (< 1 s), short (2–5 s), and long (> 5 s). In Study II, a different cohort of 48 people with PD (with and without FoG) wore 3 wearable sensors on their feet and lumbar region for 7 days. Our primary outcome measures for freezing were the % time spent freezing and its variability. Results We showed moderate to good agreement in the number of FoG episodes detected in the laboratory (Study I) between clinical raters and the algorithm (if wearable sensors were placed on the feet) for short and long FoG episodes, but not for very short FoG episodes. When extending this methodology to unsupervised home monitoring (Study II), we found that percent time spent freezing and the variability of time spent freezing differentiated between people with and without FoG (p < 0.05), and that short FoG episodes account for 69% of the total FoG episodes. Conclusion Our findings showed that objective measures of freezing in PD using inertial sensors on the feet in the laboratory are matching well with clinical scores. Although results found during daily life are promising, they need to be validated. Objective measures of FoG with wearable technology during community-living would be useful for managing this distressing feature of mobility disability in PD.
This study aimed to determine the most sensitive objective measures of balance dysfunction that differ between people with Parkinson’s Disease (PD) and healthy controls. One-hundred and forty-four people with PD and 79 age-matched healthy controls wore eight inertial sensors while performing tasks to measure five domains of balance: standing posture (Sway), anticipatory postural adjustments (APAs), automatic postural responses (APRs), dynamic posture (Gait) and limits of stability (LOS). To reduce the initial 93 measures, we selected uncorrelated measures that were most sensitive to PD. After applying a threshold on the Standardized Mean Difference between PD and healthy controls, 44 measures remained; and after reducing highly correlated measures, 24 measures remained. The four most sensitive measures were from APAs and Gait domains. The random forest with 10-fold cross-validation on the remaining measures (n = 24) showed an accuracy to separate PD from healthy controls of 82.4%—identical to result for all measures. Measures from the most sensitive domains, APAs and Gait, were significantly correlated with the severity of disease and with patient-related outcomes. This method greatly reduced the objective measures of balance to the most sensitive for PD, while still capturing four of the five domains of balance.
Background and purpose Recent findings suggest that a gait assessment at a discrete moment in a clinic or laboratory setting may not reflect functional, everyday mobility. As a step towards better understanding gait during daily life in neurological populations, we compared gait measures that best discriminated people with multiple sclerosis (MS) and people with Parkinson’s Disease (PD) from their respective, age-matched, healthy control subjects (MS-Ctl, PD-Ctl) in laboratory tests versus a week of daily life monitoring. Methods We recruited 15 people with MS (age mean ± SD: 49 ± 10 years), 16 MS-Ctl (45 ± 11 years), 16 people with idiopathic PD (71 ± 5 years), and 15 PD-Ctl (69 ± 7 years). Subjects wore 3 inertial sensors (one each foot and lower back) in the laboratory followed by 7 days during daily life. Mann–Whitney U test and area under the curve (AUC) compared differences between PD and PD-Ctl, and between MS and MS-Ctl in the laboratory and in daily life. Results Participants wore sensors for 60–68 h in daily life. Measures that best discriminated gait characteristics in people with MS and PD from their respective control groups were different between the laboratory gait test and a week of daily life. Specifically, the toe-off angle best discriminated MS versus MS-Ctl in the laboratory (AUC [95% CI] = 0.80 [0.63–0.96]) whereas gait speed in daily life (AUC = 0.84 [0.69–1.00]). In contrast, the lumbar coronal range of motion best discriminated PD versus PD-Ctl in the laboratory (AUC = 0.78 [0.59–0.96]) whereas foot-strike angle in daily life (AUC = 0.84 [0.70–0.98]). AUCs were larger in daily life compared to the laboratory. Conclusions Larger AUC for daily life gait measures compared to the laboratory gait measures suggest that daily life monitoring may be more sensitive to impairments from neurological disease, but each neurological disease may require different gait outcome measures.
A BS TRACT: Background: Quantitative assessment of severity of ataxia-specific gait impairments from wearable technology could provide sensitive performance outcome measures with high face validity to power clinical trials. Objectives: The aim of this study was to identify a set of gait measures from body-worn inertial sensors that best discriminate between people with prodromal or manifest spinocerebellar ataxia (SCA) and age-matched, healthy control subjects (HC) and determine how these measures relate to disease severity. Methods: One hundred and sixty-three people with SCA (subtypes 1, 2, 3, and 6), 42 people with prodromal SCA, and 96 HC wore 6 inertial sensors while performing a natural pace, 2-minute walk. Areas under the receiver operating characteristic curves (AUC) were compared for 25 gait measures, including standard deviations as variability, to discriminate between ataxic and normal gait. Pearson's correlation coefficient assessed the relationships between the gait measures and severity of ataxia.Results: Increased gait variability was the most discriminative gait feature of SCA; toe-out angle variability (AUC = 0.936; sensitivity = 0.871; specificity = 0.896) and double-support time variability (AUC = 0.932; sensitivity = 0.834; specificity = 0.865) were the most sensitive and specific measures. These variability measures were also significantly correlated with the scale for the assessment and rating of ataxia (SARA) and disease duration. The same gait measures discriminated gait of people with prodromal SCA from the gait of HC (AUC = 0.610, and 0.670, respectively). Conclusions: Wearable inertial sensors provide sensitive and specific measures of excessive gait variability in both manifest and prodromal SCAs that are reliable and related to the severity of the disease, suggesting they may be useful as clinical trial performance outcome measures.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.