Process analytical technology (PAT) has been defined by the Food and Drug Administration as a system for designing, analyzing, and controlling manufacturing through timely measurements to ensure final product quality. Based on quality-by-design (QbD) principles, real-time or near-real-time data monitoring is essential for timely control of critical quality attributes (CQAs) to keep the process in a state of control. To facilitate nextgeneration continuous bioprocessing, deployment of PAT tools for real-time monitoring is integral for process understanding and control. Real-time monitoring and control of CQAs are essential to keep the process within the design space and align with the guiding principles of QbD. The contents of this manuscript are pertinent to the online/at-line monitoring of upstream titer and downstream product quality with timely process control. We demonstrated that an ultra-performance liquid chromatography (UPLC) system interfaced with a UPLC-process sample manager (UPLC-PSM) can be utilized to measure titer and CQAs directly from bioreactors and downstream unit operations, respectively. We established online titer measurements from fed-batch and perfusion-based alternating tangential flow bioreactors as well as product quality assessments of downstream operations for real-time peak collection. This integrated, fully automated system for online data monitoring with feedback control is designed to achieve desired product quality.
Antibody disulfide bond reduction has been a challenging issue in monoclonal antibody manufacturing. It could lead to a decrease of product purity and failure to meet the targeted product profile and/or specifications. More importantly, disulfide bond reduction could also impact drug safety and efficacy. Scientists across the industry have been examining the root causes and developing mitigation strategies to address the challenge. In recent years, with the development of high titer mammalian cell culture processes to meet the rapidly growing demand for antibody biopharmaceuticals, disulfide bond reduction has been observed more frequently. Thus, it is necessary to continue evolving the disulfide reduction mitigation strategies and developing novel approaches to maintain high product quality. Additionally, in recent years as more complex molecules (such as bispecific and trispecific antibodies) emerge, the molecular heterogeneity due to incomplete formation of the interchain disulfide bonds becomes a more imperative challenging issue. Given the disulfide reduction challenges that biotech industry is facing, in this review, we provide a comprehensive scientific summary of the root cause analysis of disulfide reduction during process development of antibody therapeutics, mitigation strategies and its potential remediated recovery based on published papers. First, this paper intends to highlight different aspects of the root cause for disulfide reduction. Secondly, to provide a broader understanding of the disulfide bond reduction in downstream process, this paper discusses disulfide bond reduction impact on product stability, associated analytical methods for disulfide bond reduction detection and characterization, process control strategies as well as their manufacturing implementation. In addition, brief perspectives on the development of future mitigation strategies are also reviewed, including platform alignment, mitigation strategy application for the emerging new modalities such as bispecific and trispecific antibodies as well as using machine learning to identify molecule susceptibility of disulfide bond reduction. The data in this review are originated from the published papers.
Disulfide bond reduction, which commonly occurs during monoclonal antibody (mAb) manufacturing processes, can result in a drug substance with high levels of low molecular weight (LMW) species that may fail release specifications because the drug’s safety and the efficiency may be affected by the presence of this material. We previously studied disulfide reoxidation of mAbs and demonstrated that disulfide bonds could be reformed from the reduced antibody via redox reactions under an optimal redox condition on Protein A resin. The study here implements a redox system in a manufacturing setting to rescue the reduced mAb product and to further eliminate LMW issues in downstream processing. As such, we incorporate the optimized redox system as one of the wash buffers in Protein A chromatography to enable an on-column disulfide reoxidation to form intact antibody in vitro. Studies at laboratory scale (1 cm (ID) x 20 cm (Height), MabSelect SuRe LX) and pilot scale (30 cm (ID) x 20 cm (Height), MabSelect SuRe LX) were performed to demonstrate the effectiveness and robustness of disulfide formation with multiple mAbs using redox wash on Protein A columns. By applying this rescue strategy using ≤50 g/L-resin loading, the intact mAb purity was improved from <5% in the Protein A column load to >90% in the Protein A column elution with a product yield of >90%. Studies were also done to confirm that adding the redox wash has no negative impact on process yield or impurity removal or product quality. The rescued mAbs were confirmed to form complete interchain disulfide bonds, exhibiting comparable biophysical properties to the reference material. Furthermore, since the redox wash is followed by a bridging buffer wash before the final elution, no additional burden is involved in removing the redox components during the downstream steps. Due to its ease of implementation, significant product purity improvement, and minimal impact on other product quality attributes, we demonstrate that the on-column reoxidation using a redox system is a powerful, simple, and safe tool to recover reduced mAb during manufacturing. Moreover, the apparent benefits of using a high-pH redox wash may further drive the evolution of Protein A platform processes.
Disulfide bonds play a crucial role in folding and structural stabilization of monoclonal antibodies (mAbs). Disulfide bond reduction may happen during the mAb manufacturing process, resulting in low molecular weight species and possible failure to meet product specifications. Although many mitigation strategies have been developed to prevent disulfide reduction, to the best of our knowledge, reforming disulfide bonds from the reduced antibody in manufacturing has not previously been reported. Here, we explored a novel rescue strategy in the downstream process to repair the broken disulfide bonds via in-vitro redox reactions on Protein A resin. Redox conditions including redox pair (cysteine/cystine ratio), pH, temperature, and reaction time were examined to achieve high antibody purity and a high reaction rate. Under the optimal redox condition, >90% reduced antibody could be reoxidized to form an intact antibody on Protein A resin in an hour. In addition, this study showed high flexibility on the range of the intact mAb fraction in the initial reduced mAb sample (the lower limit of intact mAb faction could be 14% based on the data reported in this study). Furthermore, a kinetic model based on elementary oxidative reactions was constructed to help optimize the reoxidation conditions and to predict product purity. Together, the deep understanding of interchain disulfide bond reoxidation, combined with the predictive kinetic model, provided a good foundation to implement a rescue strategy to generate high-purity antibodies with substantial cost savings in manufacturing processes.
Process analytical technology (PAT) has been defined by the Food and Drug Administration (FDA) as a system for designing, analyzing, and controlling manufacturing through timely measurements to ensure final product quality. Based on qualityby-design (QbD) principles, real-time data monitoring is essential for timely control of critical quality attributes (CQAs) to keep the process in a state of control. To facilitate next-generation continuous bioprocessing, deployment of PAT tools for
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.