Southern European countries have milder climatic conditions that differ from their colder northern counterparts, which greatly influence indoor ventilation strategies. The relation between a building’s airtightness and the air change rates remains a topic to be fully tackled in these countries, since natural ventilation is very frequent. In this work, the ventilation and airtightness of a case study were analyzed in-depth to support a discussion on this topic. CO2 concentration decay and blower-door measurements were used to characterize the infiltration and ventilation conditions of the case study. The case study represents a common Portuguese situation, with highly permeable envelopes, combined with highly variable air change rates. Transient simulations were carried out for the comparison of scenarios where different configurations of possible air paths were analyzed. The simulations included both natural and mechanical ventilation scenarios. An air sweeping effect from bedroom to bathroom only occurred when the mechanical extraction ventilation (MEV) was on. Different air leakage path configurations resulted in substantial offsets, up to 63%, of the air change rate (ACH) due to natural occurring forces. The results confirmed that the relation between airtightness and air change rates should be carefully analyzed in southern European countries, as indoor air quality, comfort of occupants, and energy efficiency are highly influenced by the considered variables.
A full characterization of a building air leakage is labour intensive. As results of laboratory and mock-up experimentation rarely portray in situ conditions, the assessment of real case studies bring added value. Still, the results of experimentation of the latter face more challenges than the former. In this work a full quantitative and qualitative assessment of air leakage paths is performed, using a light steel framing (LSF) modular building with structural insulated panels (SIPs) as case study. Blower-door measurements undergo for a sealing campaign of eleven steps, a technique often described as reductive sealing. Additionally, smoke tracer measurements were carried out to visually identify the air leakage locations. The application of three regression methods resulted in different uncertainty estimates. Less than 7% of the total air leakage was not attributed to one of the considered types of air leakage paths. Assessing less impacting leakage paths first and placing similar types of air leakage paths in a consecutive sealing order seems to be the most correct strategy when using the reductive sealing technique. On average, at a reference pressure difference of 4 Pa, the sealing step uncertainty averaged, 9.9%, 18.8%, and 27.5%, depending on the method used for regression of the blower door test results. Despite the highest calculated uncertainty, literature shows that the application of the method leading to it, Weighted Line of Organic Correlation (WLOC), provides the results in closer agreement with the observed uncertainty of measurements.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.