We conclude that amiodarone is more effective than placebo in maintenance of SR at the end of 3 months following successful cardioversion and more patients continued to remain in SR even at the end of 12 months without major serious adverse effects.
We present a case of 50-year-old male having unstable angina. A rare type of single coronary artery was identified during the Coronary angiogram. The left anterior descending (LAD) and left circumflex artery (LCX) had originated from the proximal segment of right coronary artery along with significant lesion in LCX. Computed tomographic (CT) coronary angiogram confirmed the origin and course following which successful percutaneous coronary intervention (PCI) was done to LCX. The incidence of this type of coronary anomaly is 0.004%. We emphasize the importance of having a CT coronary angiogram to identify the course before the intervention. The procedural risk during PCI in patients with single coronary ostium is high. Moreover, the angulation and course of the culprit artery also pose a challenge. Good coaxial guide support by using an appropriate guiding catheter is the key to success.
An 80-year-old male patient, presented with chest pain. ECG showed ST elevation in leads V2 to V4 and T wave inversion in leads V2-V6. Check angiogram revealed ostial LMCA 70% lesion & mid-LAD 90% lesion and LCX proximal 80% lesion. Predilatation of LMCA lesion was done with 2.0 × 12 mm NC Trek balloon and the LAD lesion with 2.0 × 12 mm and 2.5 × 08 mm (NC Trek balloons). Prestenting IVUS (Intravascular ultrasound) was done with Atlantis SR pro 40 MHz 3.6 Fr catheter. IVUS showed the LAD to have a minimal lumen area of 2.6 sq mm with 90% fibrotic plaque and a vessel size of 2.5mm and the LMCA to have a minimal lumen area of 8.8 sq mm with 70% fibrotic plaque and vessel size of 3.8mm. Mid-LAD stenting was done with 2.5 × 28 mm Absorb Stent (BVS). Predilatation of LCX lesion was done with 2.5 × 08 mm NC Trek balloon. Then stenting was performed with 3.0 × 28 mm Absorb Stent (BVS). Check angiogram showed edge dissection proximal to the BVS Stent which was covered with 3.0 × 12 mm Xience Xpedtion Stent (DES). Then LMCA Stenting was done with 3.5 × 12 mm Absorb Stent. Post dilatation was done with 4.0 × 08 mm NC Trek balloon. Post Stenting LMCA - LAD IVUS was done. LMCA and LAD Stents were well opposed without any dissection or residual stenosis. TIMI III Flow was achieved in the final results.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.