Magnesium’s complete in vivo degradation is appealing for medical implant applications. Rapid corrosion and hydrogen bubble generation along with inflammatory host tissue response have limited its clinical use. Here we electropolymerized a poly (3,4-ethylenedioxythiophene) (PEDOT) and graphene oxide (GO) film directly on Mg surface. GO acted as nano-drug carrier to carry anti-inflammatory drug dexamethasone (Dex). PEDOT/GO/Dex coatings improved Mg corrosion resistance and decreased the rate of hydrogen production. Dex could be released driven by the electrical current generated from Mg corrosion. The anti-inflammatory activity of the released Dex was confirmed in microglia cultures. This PEDOT/GO/Dex film displayed the ability to both control Mg corrosion and act as an on demand release coating that delivers Dex at the corrosion site to minimize detrimental effects of corrosion byproducts. Such multi-functional smart coating will improve the clinical use of Mg implants. Furthermore, the PEDOT/GO/Drug/Mg system may be developed into self-powered implantable drug delivery devices.
Background Patient attitudes and behavior are critical to understand owing to the increasing role of patient choice. There is a paucity of investigation into the perceived credibility of online information and whether such information impacts how patients choose their surgeons. Objective The purpose of this study was to explore the attitudes and behavior of patients regarding online information and orthopedic surgeon selection. Secondary purposes included gaining insight into the relative importance of provider selection factors, and their association with patient age and education level. Methods This was a cross-sectional study involving five multispecialty orthopedic surgery groups. A total of 329 patients who sought treatment by six different orthopedic surgeons were asked to anonymously answer a questionnaire consisting of 25 questions. Four questions regarded demographic information, 10 questions asked patients to rate the importance of specific criteria regarding the selection of their orthopedic surgeon (on a 4-point Likert scale), and 6 questions were designed to determine patient attitude and behaviors related to online information. Results Patient-reported referral sources included the emergency room (29/329, 8.8%), friend (42/329, 12.8%), insurance company (47/329, 14.3%), internet search/website (28/329, 8.5%), primary care physician (148/329, 45.0%), and other (34/329, 10.3%). Among the 329 patients, 130 (39.5%) reported that they searched the internet for information before their first visit. There was a trend of increased belief in online information to be accurate and complete in younger age groups (P=.02). There was an increased relative frequency in younger groups to perceive physician rating websites to be unbiased (P=.003), provide sufficient patient satisfaction information (P=.01), and information about physician education and training (P=.03). There was a significant trend for patients that found a surgeon’s website to be useful (P<.001), with the relative frequency increased in younger age groups. Conclusions This study shows that insurance network, physician referrals, appointment availability, and office location are important to patients, whereas advertising and internet reviews by other patients were considered to be not as helpful in choosing an orthopedic surgeon. Future studies may seek to identify obstacles to patients in integrating online resources for decision-making and strategies to improve health-seeking behaviors.
Serum creatinine is a commonly used laboratory marker to assess kidney function; however, there has not been an established level of serum creatinine to predict mortality. After extensive literature review, we present a case of the highest recorded serum creatinine of 73.8 mg/dL in a 23-year-old male with the history of pediatric deceased donor kidney transplant (DDKT). He initially presented with uremia and signs of acute renal allograft failure after two months of immunosuppressive medication nonadherence, ultimately requiring emergent hemodialysis, which was complicated by new onset seizures. This was the patient’s fourth episode of late acute rejection and emphasizes the need for education of immunosuppressant adherence and periodic monitoring of renal function in high-risk patients. Though there is no known creatinine level incompatible with life, this patient appears to have the highest known serum creatinine in a uremic patient on record.
Purpose To assess the prevalence of intra-articular findings with ankle arthroscopy in patients undergoing operative fixation for ankle fractures. Methods This is a retrospective review of ankle fractures that were treated with arthroscopy and open reduction and internal fixation by a single surgeon. Between August 2016 and July 2018, operative reports, office notes, and images were reviewed to identify intra-articular pathology and fracture type. An analysis was performed with regard to fracture type, presence and location of osteochondral lesions, loose-bodies, syndesmotic injury, and deltoid injury. Results Fifty-seven ankle fractures were identified that met inclusion criteria. In total, 84.2% of the fractures had intra-articular pathology, most commonly a syndesmotic injury followed by presence of intra-articular loose bodies and osteochondral defects. Conclusions In our study, use of arthroscopy before open ankle fracture fixation identified intra-articular pathology in 84.2% of subjects. The most common pathology was syndesmotic injury. The addition of an arthroscopic assessment in patients with operatively treated ankle fractures may help improve treatment provided to patients during ankle fracture surgery. Level of Evidence Level 4 Therapeutic Case Series.
Olecranon fractures are common and frequently require surgical intervention when they are displaced or unstable. Treatment is largely dictated by fracture type and surgeon preference. Traditional methods of fixation, including tension band wiring and locking plate fixation, have adequate union rates; however, both techniques are associated with increased reoperation rates due to symptomatic hardware. The aim of this article is to describe a technique using a lowprofile, suture anchor tension band construct for simple transverse olecranon fractures, triceps avulsions, and olecranon osteotomies. The goal of this technique is to produce stable fixation and allow early range of motion while mitigating the reoperation rate caused by symptomatic or prominent hardware with olecranon plate fixation during fracture and olecranon osteotomies.
Background There are various algorithms for the treatment of prosthetic joint infections (PJI). Currently, a two-stage hip exchange is considered the "gold standard" of care for treatment of chronic hip PJIs. However, there has been recent debate whether a one-or two-stage exchange offers the correct treatment. One-stage exchange arthroplasty has particularly gained interest due to less morbidity, mortality, and functional impairment. Methods In a retrospective case series, the outcome of patients with chronic hip PJIs treated with our one-stage exchange arthroplasty was analyzed. Between January 2015 and January 2020, eight patients underwent a one-stage exchange hip arthroplasty by a single surgeon at a single institution for a chronically infected total hip arthroplasty (THA). Original diagnosis of PJI was made in accordance with the 2011 version of the Musculoskeletal Infection Society (MSIS) criteria. The femoral stem was cemented with antibioticimpregnated cement, and the polyethylene acetabular liner was cemented directly onto the acetabular bone with antibiotic-impregnated cement. Results Of the eight patients, three were female and five were male with a mean age of 70.5 years (SD 11.2, range 53-87). Six patients (75%) had infection eradication with retention of a stable implant and no additional surgery at a mean follow-up of 35.7 months (range 17-50). One patient (12.5%) underwent closed reduction for a dislocated THA at one month; however, this patient remained infection-free at the most recent follow-up of 41 months. One patient (12.5%) who was the oldest patient (87 years) died 18 days postoperatively. Overall, all living patients (87.5%) retained their one-stage exchange THA. One patient (12.5%, CI 95% 0.3-52.7) required additional surgery in the form of a closed reduction and zero patients (0.0%, CI 95% 0.0-36.9) required additional open surgery. Conclusion Single-stage exchange arthroplasty with an antibiotic-impregnated cemented femoral stem and antibioticimpregnated cemented polyethylene acetabular liner may be a useful option for the treatment of chronic hip PJIs. Our case series provides evidence that infection eradication and function preservation are possible using our one-stage exchange arthroplasty technique in a chronically infected THA. However, a multi-center study with randomization is necessary to further validate our results.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.