A previously healthy 21-year-old man presented with back pain, bilateral extremity pain, and right lower extremity weakness, paresthesias, and swelling. Sonographic examination revealed diffuse deep vein thrombosis (DVT) in the femoral and popliteal venous system. CT imaging revealed hypoplasia of the hepatic inferior vena cava (IVC) segment with formation of multiple varices and collateral veins around the kidneys. Hematologic workup also discovered a factor V Leiden mutation, further predisposing the patient to DVT. The rare, often overlooked occurrence of attenuated IVC, especially in the setting of hypercoagulable state, can predispose patients to significant thrombosis.
Synthetic marijuana is an uptrending designer drug currently widely spread in the US. We report a case of acute deterioration of nonischemic left ventricular dysfunction after exposure to synthetic marijuana. This case illustrates the importance of history taking in cardiac patients and identifies a negative cardiovascular effect of synthetic marijuana known as K2, not yet well detected by urine toxicology screening tools.
A 73-year-old female with multiple comorbidities including coronary artery disease was admitted for an elective PCI of a lesion detected in the RCA. On the day of the planned PCI, shortly after right femoral artery cannulation, the patient developed a sudden complete heart block requiring the administration atropine and insertion of a temporary pacemaker. Concomitantly, the patient developed acute pulmonary edema, hypotension, and hypoxia requiring intubation for mechanical ventilation. Vasopressors were administered. A coronary angiogram showed patent left and right coronary arteries, unchanged when compared to the previous angiogram. An echocardiogram performed in the cardiac catheterization lab revealed global hypokinesis of the left and right ventricles, with severe LV systolic dysfunction (EF < 20%). Following an insertion of an intra-aortic balloon pump, the patient was transferred to the CICU. A repeat echocardiogram in the CICU two hours later revealed a classical echocardiographic presentation of Takotsubo syndrome, apical hypokinesis. By the next morning the patient's hemodynamic status significantly improved, the balloon pump was removed, and vasopressors were discontinued. Another echocardiogram was performed 24 hours after the event occurred and revealed a marked improvement in LV systolic function (EF 60%), with complete resolution of apical and septal wall motion abnormalities. Three days after the event, the patient was successfully discharged and asymptomatic at two-month follow-up. This case illustrates an atypical presentation of Takotsubo syndrome that was witnessed from onset to its complete resolution during the patient's hospital stay.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.