BackgroundAn accelerometer-based handheld navigation system (HHNS) for total knee arthroplasty (TKA) does not require a large console needed for computer-assisted navigation systems and has been shown to decrease component malalignment in TKA. The study aimed to use HHNS with conventional instrumentation to compare the radiological evaluation and functional outcomes of TKA. Materials and methodsThis was a multi-surgeon, prospective, assessor-blinded comparative study of 122 patients undergoing unilateral TKA. We used a stratified randomized sampling method to select 35/48 patients undergoing TKA using a handheld navigation system and 35/74 patients undergoing TKA using conventional instrumentation and divided them into two groups: the HHNS group and (conventional) CONV group. Postoperative radiographic evaluation was based on the tibial and femoral alignment angle, posterior tibial slope, and tibiofemoral angle measured from full-length lower-limb anteroposterior and lateral views of the knee. The Oxford Knee Score (OKS) and Knee Society Score (KSS) with a two-year serial follow-up were used to evaluate functional outcomes. ResultsThe mean tibial alignment angle and posterior tibial slope were 0.78° ± 1.27° and 4.38° ± 0.86°, respectively, in the HHNS cohort and 2.63° ± 1.54° and 2.12° ± 1.82°, respectively, in the CONV group (p < 0.001). There was no significant difference in the femoral alignment angles. The overall alignment using the mean tibiofemoral angle was 179.21° ± 1.82° in the HHNS group and 177.31° ± 2.18° in the CONV group (p = 0.002). There were no significant differences in the KSS and OKS at the two-year follow-up between the groups. ConclusionsThe use of HHNS in TKA significantly increased accuracy in limb and implant alignment, but there was no significant difference in the two-years functional outcomes.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.