The objective of this study was to compare the reproductive efficiency of dairy buffaloes undergoing fixed-time artificial insemination (FTAI) protocols based on progesterone/estrogen (P4/E2) and eCG during unfavorable breeding season using cooled (CS) and frozen semen (FS). A total of 446 buffaloes (> 40 days postpartum) were randomly distributed into four blocks (years): B1-2014 (n = 143), B2-2015 (n = 34), B3-2016 (n = 90), and B4-2017 (n = 179). Each block was subdivided into two (AI with CS and FS using the same ejaculate of each bull). Thus, the block subdivision was as follows: B1 (CS = 71 and FS = 72); B2 (CS = 18 and FS = 16); B3 (CS = 47 and FS = 43); and B4 (CS = 90 and FS = 89). The ejaculates of eight Murrah bulls collected using an artificial vagina were divided into two aliquots: one aliquot was diluted in Botu-Bov® commercial extender and cooled (BB-CS), and the other was diluted in the same extender and frozen (BB-FS). BB-CS aliquots were cooled at 5 °C/24 h using a refrigerator. BB-FS group aliquots were also cooled, and after equilibrating at 5 °C for 4 h, were placed in a 21-L Styrofoam box, 5 cm above the surface of liquid nitrogen. In the afternoon (A) on D0 (2:00 p.m.) the animals received EB 2.0 mg IM (Estrogin®) and an ear implant (CRESTAR® 3.0 mg P4). At D9 (A), the implant was removed, and the animals received eCG 400 IU IM (Folligon® 5000) + Cloprostenol PGF2α 0.530 mg IM (Sincrocio®). At D10 (A), the animals received EB 1.0 mg IM (Estrogin®), and at D12 (8:00 a.m.), AI was performed. At D42, pregnancy was diagnosed via ultrasonography. Total CRs were 48.2% CS and 34.6% FS for years 2014 to 2017, with a significant difference of 13.7% (P<0.05). In conclusion, cooled semen resulted in higher CR than frozen semen in dairy buffaloes under the P4/E2 and eCG FTAI during the unfavorable reproductive season.
This study investigated in vitro the efficacy of four different extenders (TES-TRIS and TRIS with LDL low-density lipoprotein at concentrations of 10 or 5%) on the longevity of buffalo sperm in the refrigeration process at 5ºC. Sperm motility was assessed every 24 hours up to 72 hours of incubation using computer assisted sperm analysis and sperm membrane integrity was examined by the hypoosmotic test (HOST) at T1, T24, T48 and T72 hours. Eleven buffaloes (1 ejaculate per buffalo) of the Murrah breed were used, ranging in age from 4 to 5 years. Immediately after collection, each ejaculate was fractionated into 4 aliquots, and each aliquot was diluted in one of four diluents to obtain 50x106SPTZ/mL. The samples were packed in 0.5mL straws and refrigerated (-0.25°C/min) to 5°C and maintained at this temperature until evaluation. Prior to evaluation the samples were heated at 37°C for 30 seconds. The statistical package used for analysis was STATA 12.0 "Statistical Analysis Software" and means were compared by the Friedman test (P<0.05). The results of sperm kinetics and HOST indicate that the TRIS diluent with 10% LDL could be a promising alternative for semen refrigeration at 5ºC, to be used in conventional and fixed time artificial insemination.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
334 Leonard St
Brooklyn, NY 11211
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.