These short-term outcomes are promising and show a high success rate for the uterosacral ligament suspension at the time of a hysterectomy regardless of whether it was performed vaginally or robotically.
Introduction and Hypothesis
This study evaluates the necessity and effect of an indwelling transurethral catheter in the early postoperative period following a robotic-assisted laparoscopic sacrocolpopexy.
Methods
This was a randomized clinical trial of patients who underwent a robotic sacrocolpopexy for pelvic organ prolapse. Patients were randomized to have their transurethral catheter removed 6 hours postoperative (intervention group) or the morning following surgery (control group). Our primary outcome was to compare the number of patients diagnosed with postoperative incomplete bladder empyting in each group. A sample size of 36 patients per group was needed to detect a 25% difference between the 2 groups. Anticipating a 20% patient withdrawal rate, we estimated that we would need a total of 88 participants. Outcome variable was analyzed using χ2 test, Fisher exact test, Mann-Whitney U test, 2-proportions test, and 2-sample t test.
Results
From December 2015 through May 2017, 88 women were randomized and analyzed: 44 in the intervention group and 44 in the control group. Women in the intervention group were more likely to be diagnosed with incomplete bladder emptying, 14 (31%) of 44, compared with the control group, 2 (4.5%) of 44, P <0.001. Rate of urinary tract infections within the 30-day postoperative period was also increased in the intervention group, 4 (9%) of 44, compared with 0 in the control group. Postoperative complications were similar between groups.
Conclusions
In women undergoing a robotic sacrocolpopexy, early transurethral catheter removal (6 hours postoperative) is associated with an increased rate of incomplete bladder emptying, recatheterization, and urinary tract infections.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.