The steam generator in a nuclear power plant is a type of heat exchanger in which heat transfer occurs from the hot fluid in multiple channels to the cold fluid. Therefore, a uniform flow over multiple channels is necessary to improve heat exchanger efficiency. The study aims at experimentally investigating the improvement of flow uniformity by the perforated plate in the heat exchanger used for a sodium-cooled fast reactor stream generator. A 1/4-scale experimental model for one heat exchanger unit with 33 × 66 channels was manufactured. The working fluid was water. A perforated plate was systematically designed using numerical simulations to improve the flow uniformity over the 33 × 66 channels. As a result, the flow uniformity greatly improved at a slight cost of pressure drop. To validate the numerical results, planar particle image velocimetry measurements were performed on the selected planes in the inlet and outlet headers. The experimental velocity profiles near the exits of the channels were compared with numerical simulation data. The experimental profiles agreed with the numerical data well. Both the numerical simulation and the experimental results showed a slight increase in pressure drop, despite significant improvement in the flow uniformity.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.