The aim of this study was to investigate the reliability and concurrent validity of a commercially available Xsens MVN BIOMECH inertial-sensor-based motion capture system during clinically relevant functional activities. A clinician with no prior experience of motion capture technologies and an experienced clinical movement scientist each assessed 26 healthy participants within each of two sessions using a camera-based motion capture system and the MVN BIOMECH system. Participants performed overground walking, squatting, and jumping. Sessions were separated by 4 ± 3 days. Reliability was evaluated using intraclass correlation coefficient and standard error of measurement, and validity was evaluated using the coefficient of multiple correlation and the linear fit method. Day-to-day reliability was generally fair-to-excellent in all three planes for hip, knee, and ankle joint angles in all three tasks. Within-day (between-rater) reliability was fair-to-excellent in all three planes during walking and squatting, and poor-to-high during jumping. Validity was excellent in the sagittal plane for hip, knee, and ankle joint angles in all three tasks and acceptable in frontal and transverse planes in squat and jump activity across joints. Our results suggest that the MVN BIOMECH system can be used by a clinician to quantify lower-limb joint angles in clinically relevant movements.
Subgroups of NSCLBP had similar neutral spinal position deficits regarding error magnitude and variability, but subclassification revealed clear subgroup differences in the direction of the deficit. The trunk muscle activation was shown to be largely nondiscriminatory between subgroups, with the exception of superficial lumbar multifidus.
Purpose A multidimensional classification approach suggests that motor control impairment subgroups exist in non-specific chronic low back pain (NSCLBP). Differences in sitting lumbar posture have been identified between two such subgroups [flexion pattern (FP) and active extension pattern (AEP)] and healthy individuals; however, functional spinal movement has not been explored. This study will evaluate whether NSCLBP subgroups exhibit regional spinal kinematic differences, compared to healthy individuals, during functional tasks. Methods Observational, cross-sectional study design. Spinal kinematics of 50 NSCLBP subjects (27 FP, 23 AEP) and 28 healthy individuals were investigated using 3D motion analysis (Vicon TM ) during functional tasks [reaching upwards, step down, step up, lifting, and replacing a box, stand-to-sit, sit-to-stand, bending to retrieve (and returning from retrieving) a pen from the floor]. Mean sagittal angle for the total thoracic, total lumbar, upper thoracic, lower thoracic, upper lumbar, and lower lumbar regions between groups was compared. Results Significant differences were observed in lower thoracic and upper lumbar regions between NSCLBP subgroups during most tasks. Significant differences were observed between the FP and healthy group in the lower thoracic region during stand-to-sit-to-stand tasks and bending (and returning from) to retrieve a pen from the floor. All significant results demonstrated the FP group to operate in comparatively greater flexion. Conclusions The thoraco-lumbar spine discriminated between FP and AEP, and FP and healthy groups during functional tasks. FP individuals demonstrated more kyphotic thoraco-lumbar postures, which may be pain provocative. No significant differences were observed between AEP and healthy groups, suggesting that alternative mechanisms may occur in AEP.
Anterior cruciate ligament (ACL) injury can result in failure to return to pre-injury activity levels and future osteoarthritis predisposition. Single leg hop is used in late rehabilitation to evaluate recovery and inform treatment but biomechanical understanding of this activity is insufficient.This study investigated single leg hop for distance aiming to evaluate if ACL patients had recovered: (1) landing strategies and (2) medio-lateral knee control. We hypothesized that patients with reconstructive surgery (ACLR) would have more similar landing strategies and knee control to healthy controls than patients treated conservatively (ACLD).16 ACLD and 23 ACLR subjects were compared to 20 healthy controls (CONT). Kinematic and ground reaction force data were collected while subjects hopped their maximum distance. The main output parameters were hop distance, peak knee flexor angles and extensor moments and Fluency (a measure introduced to represent medio-lateral knee control). Statistical differences between ACL and control groups were analyzed using a general linear model univariate analysis, with COM velocity prior to landing as covariate.Hop distance was the smallest for ACLD and largest for CONT (p<0.001; ACLD 57.1±14.1; ACLR 75.1±17.8; CONT 77.7±14.07% height). ACLR used a similar kinematic strategy to CONT, but had a reduced peak knee extensor moment (p<0.001; ACLD 0.32±0.14; ACLR 0.31±0.16; CONT 0.42±0.13 BW.height). Fluency was reduced in both ACLD and ACLR (p=0.006; ACLD 0.13±0.34; ACLR 0.14±0.34; CONT 0.17±0.41 s).Clinical practice uses hopping distance to evaluate ACL patients' recovery. This study demonstrated that aspects such as movement strategies and knee control need to be evaluated.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.