participated in data collection, data analysis, and critical revision of the article. C.I. and A.G. contributed reagents, analytic tools, and participated in data analysis. M.R. and H.U. participated in data analysis and statistical support. D.Ö. and J.T. supported the study, contributed research advice, and revised the article critically.
Summary
Between 2000 and 2014, five patients received bilateral hand (n = 3), bilateral forearm (n = 1), and unilateral hand (n = 1) transplants at the Innsbruck Medical University Hospital. We provide a comprehensive report of the long‐term results at 20 years. During the 6–20 years follow‐up, 43 rejection episodes were recorded in total. Of these, 27.9% were antibody‐related with serum donor‐specific alloantibodies (DSA) and skin‐infiltrating B‐cells. The cell phenotype in rejecting skin biopsies changed and C4d‐staining increased with time post‐transplantation. In the long‐term, a change in hand appearance was observed. The functional outcome was highly depending on the level of amputation. The number and severity of rejections did not correlate with hand function, but negatively impacted on the patients´ well‐being and quality of life. Patient satisfaction significantly correlated with upper limb function. One hand allograft eventually developed severe allograft vasculopathy and was amputated at 7 years. The patient later died due to progressive gastric cancer. The other four patients are currently rejection‐free with moderate levels of immunosuppression. Hand transplantation remains a therapeutic option for carefully selected patients. A stable immunologic situation with optimized and individually adopted immunosuppression favors good compliance and patient satisfaction and may prevent development of DSA.
Hypothermic machine perfusion (HMP) has been introduced as an alternative to static cold storage (SCS) in kidney transplantation, but its true benefit in the clinical routine remains incompletely understood. The aim of this study was to assess the effect of HMP vs. SCS in kidney transplantation. All kidney transplants performed between 08/2015 and 12/2019 (n = 347) were propensity score (PS) matched for cold ischemia time (CIT), extended criteria donor (ECD), gender mismatch, cytomegalovirus (CMV) mismatch, re-transplantation and Eurotransplant (ET) senior program. A total of 103 HMP and 103 SCS instances fitted the matching criteria. Prior to PS matching, the CIT was longer in the HMP group (17.5 h vs. 13.3 h; p < 0.001), while the delayed graft function (DGF) rates were 29.8% and 32.3% in HMP and SCS, respectively. In the PS matched groups, the DGF rate was 64.1% in SCS vs. 31.1% following HMP: equivalent to a 51.5% reduction of the DGF rate (OR 0.485, 95% CI 0.318–0.740). DGF was associated with decreased 1- and 3-year graft survival (100% and 96.3% vs. 90.8% and 86.7%, p = 0.001 and p = 0.008) or a 4.1-fold increased risk of graft failure (HR = 4.108; 95% CI: 1.336–12.631; p = 0.014). HMP significantly reduces DGF in kidney transplantation. DGF remains a strong predictor of graft survival.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.