We report the realization of a new polarization entangled photon-pair source based on a titanium-indiffused waveguide integrated on periodically poled lithium niobate pumped by a CW laser at 655 nm. The paired photons are emitted at the telecom wavelength of 1310 nm within a bandwidth of 0.7 nm. The quantum properties of the pairs are measured using a two-photon coalescence experiment showing a visibility of 85%. The evaluated source brightness, on the order of 10(5) pairs s(-1)GHz(-1)mW(-1), associated with its compactness and reliability, demonstrates the source's high potential for long-distance quantum communication.
We evaluated the efficacy of Botulinum toxin type A (BTXA) as an alternative to surgical intervention to facilitate phonation in 34 laryngectomized patients (31 males and 3 women) who were unable to produce tracheoesophageal voice because of spasm of the middle and inferior pharyngeal constrictor muscles (PCM). EMG was recorded to confirm activity in these muscles during attempted vocalization. Parapharyngeal nerve block (Carbocaine 2%, 5 cc) was used to demonstrate short-term fluent voice after relaxation of the pharyngeal constrictor muscle. At a later occasion, 100 U of Botox (Allergan) in ten patients and 50 U in two patients were injected unilaterally at one location in the PCM percutaneously under EMG guidance. All patients then underwent a voice therapy program. In 11 out of 12 patients an improvement of phonation was evident after 24-48 h and it was long lasting. This result was also seen in a patient previously myotomized without improvement. Only one patient needed to be reinjected every 3 months. At a follow-up after 3 months the EMG recorded in four patients showed a low-amplitude or complete absence of activity in the treated muscle. No side effects developed. BTX therapy, especially when associated with the speech therapy, is efficacious in restoring voice to laryngectomees who are unable to voice because of spasm of the PCMs. Our results confirm previous reports. This method is our approach of choice in managing PCM spasm because it is non-invasive, not painful, has few or no side effects, and is frequently long-lasting.
School of ICT, Royal Institute of Technology (KTH), Electrum 229, Kista, SE-16440, Sweden Abstract: Real-time transmission of 14-GBd 4-PAM signal is demonstrated by combining a commercial 1.55-µm DML with a silicon MRR. BER below the HD-FEC threshold is measured after 26-km SSMF transmission without offline digital signal processing.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.