This work introduces a computational framework for applying absolute electrical impedance tomography to head imaging without accurate information on the head shape or the electrode positions. A library of fifty heads is employed to build a principal component model for the typical variations in the shape of the human head, which leads to a relatively accurate parametrization for head shapes with only a few free parameters. The estimation of these shape parameters and the electrode positions is incorporated in a regularized Newton-type output least squares reconstruction algorithm. The presented numerical experiments demonstrate that strong enough variations in the internal conductivity of a human head can be detected by absolute electrical impedance tomography even if the geometric information on the measurement configuration is incomplete to an extent that is to be expected in practice.
<abstract><p>We consider the problem of the detection of brain hemorrhages from three-dimensional (3D) electrical impedance tomography (EIT) measurements. This is a condition requiring urgent treatment for which EIT might provide a portable and quick diagnosis. We employ two neural network architectures - a fully connected and a convolutional one - for the classification of hemorrhagic and ischemic strokes. The networks are trained on a dataset with $ 40\, 000 $ samples of synthetic electrode measurements generated with the complete electrode model on realistic heads with a 3-layer structure. We consider changes in head anatomy and layers, electrode position, measurement noise and conductivity values. We then test the networks on several datasets of unseen EIT data, with more complex stroke modeling (different shapes and volumes), higher levels of noise and different amounts of electrode misplacement. On most test datasets we achieve $ \geq 90\% $ average accuracy with fully connected neural networks, while the convolutional ones display an average accuracy $ \geq 80\% $. Despite the use of simple neural network architectures, the results obtained are very promising and motivate the applications of EIT-based classification methods on real phantoms and ultimately on human patients.</p></abstract>
Medical ultrasound imaging is the most widespread real-time noninvasive imaging system and its formulation comprises signal transmission, signal reception, and image formation. Ultrasound signal transmission modelling has been formalized over the years through different approaches by exploiting the physics of the associated wave problem. This work proposes a novel computational framework for modelling the ultrasound signal transmission step in the time-frequency domain for a linear-array probe. More specifically, from the impulse response theory defined in the time domain, we derived a parametric model in the corresponding frequency domain, with appropriate approximations for the narrowband case. To validate the model, we implemented a numerical simulator and tested it with synthetic data. Numerical experiments demonstrate that the proposed model is computationally feasible, efficient, and compatible with realistic measurements and existing state-of-the-art simulators. The formulated model can be employed for analyzing how the involved parameters affect the generated beam pattern, and ultimately for optimizing measurement settings in an automatic and systematic way.
This work considers electrical impedance tomography imaging of the human head, with the ultimate goal of locating and classifying a stroke in emergency care. One of the main difficulties in the envisioned application is that the electrode locations and the shape of the head are not precisely known, leading to significant imaging artifacts due to impedance tomography being sensitive to modeling errors. In this study, the natural variations in the geometry of the head and skull are modeled based on a library of head anatomies. The effect of these variations, as well as that of misplaced electrodes, on (absolute) impedance tomography measurements is in turn modeled by the approximation error method. This enables reliably reconstructing the conductivity perturbation caused by the stroke in an average head model, instead of the actual head, relative to its average conductivity levels. The functionality of a certain edge-preferring reconstruction algorithm for locating the stroke is demonstrated via numerical experiments based on simulated three-dimensional data.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.