Although masticatory function is impaired by the loss of natural teeth and dentures can restore only a fraction of such function, patients can benefit from a simplified protocol for complete denture fabrication to the same extent they would by conventional techniques.
Among the factors that contribute to the papilla formation and crestal bone preservation between contiguous implants, this animal study clinically and radiographically evaluated the interimplant distances (IDs) of 2 and 3 mm and the placement depths of Morse cone connection implants restored with platform switch. Bilateral mandibular premolars of 6 dogs were extracted, and after 12 weeks, the implants were placed. Four experimental groups were constituted: subcrestally with ID of 2 mm (2 SCL) and 3 mm (3 SCL) and crestally with ID of 2 mm (2 CL) and 3 mm (3 CL). Metallic crowns were immediately installed with a distance of 3 mm between the contact point and the bone crest. Eight weeks later, clinical measurements were performed to evaluate papilla formation, and radiographic images were taken to analyze the crestal bone remodeling. The subcrestal groups achieved better levels of papillae formation when compared with the crestal groups, with a significant difference between the 3 SCL and 3 CL groups (P = .026). Radiographically, the crestal bone preservation was also better in the subcrestal groups, with statistically significant differences between the 2SCL and 2CL groups (P = .002) and between the 3SCL and 3CL groups (P = .008). With the present conditions, it could be concluded that subcrestal implant placement had a positive impact on papilla formation and crestal bone preservation, which could favor the esthetic of anterior regions. However, the IDs of 2 and 3 mm did not show significantly different results.
The subcrestal placement of contiguous Morse cone connection implants with 'platform shifting' was more efficient in preserving the interimplant crestal bone. The IDs of 2 and 3 mm did not affect the bone remodeling significantly under the present conditions.
The retention of removable dentures by mini-implants is a relatively recent treatment modality and may lead to minimal post-operative trauma. This study compared post-operative pain and discomfort following the insertion of mini-implants (two or four) or two standard-size implants for the retention of mandibular overdentures. One hundred and twenty edentulous participants (mean age 59.5 ± 8.5 years) were randomly allocated into three groups according to received treatment: (GI) four mini-implants, (GII) two mini-implants or (GIII) two standard implants. Seven days after implant insertion, patients answered questions (100-mm VAS) relating to pain, swelling, and discomfort with chewing, speech and hygiene, considering their experiences during the 1st and 6th day. Groups were compared by two-way anova (α = 0.05). All participants (GI: 38; GII: 42; GIII: 40) were analysed after 7 days. At the 6th day, GI felt significantly higher pain than GII and GIII. GI also reported more difficulty in performing oral hygiene practices than GIII during the 1st day. There was no significant difference between groups for the other questions and periods. No participant suffered unexpected side effects. The use of four mini-implants induces more intense post-operative pain at the 6th day than the insertion of two mini- or conventional fixtures, as well as more difficult oral hygiene on the 1st day. Clinicaltrials.gov, NCT01411683; FAPESP, 2011/00688-7 and 2011/23347-0.
This study evaluated the abrasiveness of mechanical and combined methods of denture hygiene, by the analysis of mass loss and surface roughness. Acrylic resin specimens (Plexiglass) were brushed by a tooth brushing machine (Mavtec) with a soft brush (Tek) and water (control) or four dentifrices (Sorriso, Colgate, Polident and Corega) (Experimental groups) for 50 min, representing one year of brushing (mechanical method). After brushing, the specimens were immersed in 0.5% sodium hypochlorite simulating a daily cleaning of 20 min for one year (combined method). Distilled water (23 ºC) was employed as control. The mass loss (g) was analyzed by an analytical balance and the surface roughness (μm) by a rugosimeter. Data were subjected to ANOVA and Bonferroni test (α=0.05). Polident dentifrice showed lowest values of mass loss for both methods (mechanical: -0.0072±0.0017, combined:-0.011±0.002) and the combined method resulted in greater mass loss than the mechanical, except for Corega. For the surface roughness, after the mechanical method, the lowest values were registered for water (-0.007±0.016) and Polident (0.402±0.378); for the combined method, water (-0.063±0.013) showed the lowest values; there was no statistically significant difference between methods. It was concluded that Polident was the less abrasive dentifrice and the association between chemical and mechanical methods increased the mass loss but did not change the surface roughness of specimens.
Distances of 1, 2, and 3 mm between implants do not result in statistically significant differences on TI-BC and TI-BIC around submerged or non-submerged implants with a Morse cone connection and a platform switch.
Duplex Doppler sonography is an excellent method for screening patients suspected to have TRAS and can help select which of those patients should undergo digital subtraction arteriography.
Mandibular overdentures retained by 2 conventional implants have been considered the standard of care for complete edentulism, according to the McGill and York consensuses. However, many patients refuse this treatment modality due to the associated costs and postsurgical discomfort. Mini-implants have the chance to overcome these limitations due to their potentially lower costs and a relatively uncomplicated surgical technique. This study compared treatment costs and incremental costeffectiveness following the insertion of mini-implants (2 or 4) or 2 standardsize implants for the retention of mandibular overdentures, by means of a randomized clinical trial. In total, 120 edentulous participants (mean age 59.5 ± 8.5 y) were randomly allocated into 3 groups according to treatment received: 4 mini-implants (group 1), 2 mini-implants (group 2), or 2 standard implants (group 3). Treatment costs and outcomes (Oral Health Impact Profile for Edentulous [OHIP-EDENT] and satisfaction with the dentures) were evaluated after 6 mo. Incremental cost-effectiveness ratios (ICERs) were calculated for each intervention in terms of cost per 1-point change in patient outcomes. A 1-way sensitivity analysis was performed considering a 95% confidence interval variation in cost and outcome parameters, represented in tornado diagrams. Overall treatment cost was the lowest for group 2 (average cost: US$318.08), followed by group 1 (US$510.75) and group 3 (US$566.13). Groups did not differ in terms of the length of unscheduled appointments and time spent by participants. In summary, our findings indicate that mandibular overdentures retained by 2 or 4 mini-implants are less costly compared to 2-implant overdentures. Despite the lower costs of overdentures retained by 2 mini-implants, those retained by 4 mini-implants showed further improvement in patient-reported outcomes and reduced costs compared to standard implants (ClinicalTrials.gov NCT01411683). Knowledge Transfer Statement: This report shows that mini-implant retained overdentures are less costly than overdenture treatment on 2 standard-sized implants. Treatment with 2 mini-implants is an effective procedure to substantially save resources, whereas treatment with 4 mini-implants provides better results from a patient perspective combined with slightly reduced costs compared to the treatment with 2 standard implants. Therefore, mini-implant overdentures may be effective and more accessible than overdentures on 2 standard-size implants for those with limited incomes.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.