Hydroxyurea, a myelosuppressive agent, is the only effective drug proven to reduce the frequency of painful episodes. It raises the level of HbF and the haemoglobin level. It usually decreases the rate of painful episodes by 50 %. It was first tested in sickle cell disease in 1984. It also decreases the rate of ACS episodes and blood transfusions by *50 % in adults. It was developed as an anticancer drug and has been used to treat myeloproliferative syndromes-leukemia, melanoma, and ovarian cancer. It was approved for use by FDA in adults. Side effects includes neutropenia, bone marrow suppression, elevation of hepatic enzymes, anorexia, nausea, vomiting and infertility.
Patients with HCC in the absence of liver cirrhosis are more likely to present at an older age with larger tumor and have higher rates of tumor recurrence. Studies to assess the cost-effectiveness of HCC surveillance in this group should be conducted.
AimGuided by the ALARA - “As Low As Reasonably Achievable” principle in radiation safety, a quality improvement project to optimise the bedside diagnostic imaging process to the best standards of care was conducted over a six month period. The goal was too reduce the radiation hazard opportunities in the neonatal intensive care unit by at least 75% from the existing level at Q2/2015, within 6 months.MethodsThe existing bedside imaging process was critically analysed and the following quality improvement initiatives were implemented namely, mandatory lead protective gear to healthcare staff, gonadal shield for neonates, guidelines for optimal collimation of X-ray beam and optimal positioning of neonates. Radiation dosimetry results, regular staff awareness sessions and strong collaboration between neonatologists, radiologists, radiographers and neonatal nurses helped to ensure compliance to the revised imaging process. Radiation hazard opportunities were measured by analysing all radiographs done during the period under baby exposure and healthcare staff exposure categories.Summary of resultsRadiation hazard opportunities were reduced by 100% to healthcare staff and 75% to neonates, and the overall reduction was 83%. The rate of discordance between radiograph request forms and images taken was measured as a surrogate marker for compliance to the project initiatives and it declined by 77%. Mandatory orientation of staff to the revised policy on the standardised diagnostic imaging process, regular radiation awareness talks and staff feedback sessions are among several measures taken to sustain the project.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.