despite the evidence-based recommendations, this study revealed a poor compliance with major guidelines on diagnosis of celiac disease. We emphasize that taking adequate number of duodenal biopsies should be implemented for an accurate diagnosis and also for the exclusion of celiac disease.
Duodenal confocal laser endomicroscopy (CLE) was carried out in six patients to compare the findings with histology. The visibility and quality of the endomicroscopy images were quantified using the following score: 0 = none; 1 = poor; 2 = fair; 3 = good. Four patients had a normal duodenal mucosa, whereas two patients in whom CLE indicated villous atrophy showed histologic features typical of celiac disease. Histology and CLE images were similar in both normal and celiac disease patients; patients with celiac disease had an average score of 3 for epithelial architecture, 3 for goblet cells, 3 for vessels, 1 for inflammatory infiltrate, and 2 for crypt visibility.
Confocal laser endomicroscopy (CLE) was carried out in seven patients with chronic watery diarrhea (three men; age range 68 - 84 years) to find the correspondence between CLE and histological findings in collagenous colitis. On the basis of the CLE images, two to five biopsies were performed in various segments of the colon. The endoscopic and histological diagnoses of collagenous colitis were made blindly. The quality of the CLE images was quantified from 0 (the endoscopist could not visualize the corresponding histologic equivalent) to 3 (the endoscopist could identify >or= 80 % of the corresponding histologic equivalent). Four out of seven patients had histological findings of collagenous colitis. Correspondence between histology and CLE images yielded the following scores: 3 for epithelial architecture, 3 for goblet cells, 3 for vessels, and 2 for inflammatory infiltrate. In collagenous colitis patients, CLE identified a well-defined "shell" around the crypts, corresponding to the increase in the thickness of the subepithelial collagenous plate evidenced by histology. CLE appears to be a promising means of identifying typical collagenous colitis features.
Background En bloc endoscopic submucosal dissection (ESD) has been recently introduced as a treatment for precancerous/ neoplastic gastrointestinal conditions. The aim of the present study was histological assessment of en bloc ESD specimens. Methods Fifty-three ESD specimens were positioned over a cellulose acetate support (40 specimens; 12 from the upper gastrointestinal tract and 28 from the lower gastrointestinal tract) or pinned with nails on polystyrene or cork (13 specimens; 7 from the upper gastrointestinal tract and 6 from the lower gastrointestinal tract). We cut consecutive 2 mm-thick sections stained with hematoxylin and eosin. From the first and the last sections, we obtained a second slide, after a 180° rotation and re-embedding. The quality of ESD samples was scored as inadequate, suboptimal and adequate, based on the amount of crushing, shearing and stretching artifacts that were scored from 0 (absent) to 2 (diffuse or maximum). From the sum of these we obtained a global artifact score (GAS). Results Removed lesions were: adenocarcinoma (5 cases), neuroendocrine tumor (NET) G1 (1 case), premalignant conditions, including adenomatous polyps (41 cases) and hyperplastic lesions (6 cases). A positive deep surgical margin was found in 8/53 cases (15%): high-and low-grade dysplastic glands were detected in 5 cases, low-grade adenocarcinoma in 2, and NET cells in 1. Dysplastic glands were detected in the lateral surgical margins of 12 ESD specimens (23%). Among the ESD specimens positioned on the cellulose acetate support, apart from the modifications due to electrocoagulation, 2 (5%) showed shearing modifications. In the group of ESD specimens fixed with nails, 5 (38%) showed shearing, 10 (77%) crushing artifacts, 11 (85%) stretching and 11 (85%) multiple holes caused by the nails. On the basis of these data all histological specimens from ESD on cellulose acetate were adequate (GAS 0-1).However, in the group of ESD fixed with nails, 1 was adequate (GAS 0), 11 suboptimal (GAS 2-5) and 1 inadequate (GAS 6). Conclusions Specific devices including cellulose support and adequate sampling blocks can be helpful to perform accurate histological assessment of ESD specimens after en bloc ESD for precancerous/neoplastic gastrointestinal lesions, with complete analysis of the status of the margins and the entirely en bloc evaluation of the lesion.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.